SPANNTOP [nova] – Maintenance
8.2 Cleaning
WARNING!
Risk of injury due to cleaning with compres-
sed air!
By cleaning the mechanic with compressed air,
fine chips may cause injuries at the eyes and
risk of cutting.
Never clean the clamping device with com-
pressed air!
Always wear personal protective equipment!
7. x
Auxiliary material required:
Ester-free, non-polar cleaning agent
Soft, lint-free cloth
Fig. 89
1. Disassemble the clamping device [see section
»Disassembling the clamping unit«].
2. Clean all the components listed below with clea-
ning agent and a cloth; remove all oil and grease
residues:
Spindle flange
Clamping unit
Taper reception and coupling area
Drawtube adapter
Threaded adapter [optional]
Cylindrical screws
3. For the SPANNTOP [nova] modular, in addition
also clean the coupling with torsional safety ele-
ment with cleaning agent and cloth; remove all oil
and grease residues.
To do this take the torsional safety element out of
the coupling groove.
99