SPANNTOP [nova] – Maintenance
8.4 Use of lubricant
With the usage of lubricant you may only use grease
that corresponds to the requirements concerning bond,
pressure-stability and solubility in lubricating coolant.
In addition no dirt particles may be in the grease; they
cause run errors if they come in in-between two mating
surfaces.
We recommend for this the following lubricant:
HAINBUCH grease
See optional Accessories
Alternatives:
Lubricant
Manufacturer
Product
Universal grease MicroGleit
GP 355
Klüber
QNB 50
Zeller & Gmelin
DIVINOL SD24440
Bremer & Leguill
RIVOLTA W.A.P.
Special grease
Klüber
MICROLUBE GL 261
101