MISCELLANEOUS
133
Note
Remote sense function for AC-INT, DC-INT, AC-SYNC
mode and 100V, 200V range and SIN wave shape and
slew rate mode on Time Only.
Display
When the remote sense function is on, the
displayed voltage value is the voltage measured at
the sense terminal and the symbol “SENS” is
displayed on the status bar for standard and
simple mode display.
SENS displayed
WARNING
Before connecting the remote sense cables, turn
off the output and peripherals. Please see page 100
for more information on the remote sense cabling
instructions.
If the remote sense wires are loose or falling
(specifically the remote sense te and the
load te & -), the display would show a
warning message as below.