APPENDIX
209
Model
ASR-2050
ASR-2050R
ASR-2100
ASR-2100R
Output voltage waveform distortion ratio, Output voltage response time,
Efficiency
Total harmonic distortion (THD)
*1
<0.2 % @50/60 Hz
<0.3 % @<500 Hz
<0.5 % @500.1 Hz to 999.9 Hz
Output voltage response time
*2
100 us (TYP)
Efficiency
*3
70 % or more
*1
At an output voltage of 50 V to 175 V / 100 V to 350 V, a load power factor of
1, and in AC and AC+DC mode.
*2
For an output voltage of 100 V / 200 V, a load power factor of 1, with respect
to stepwise change from an output current of 0 A to the maximum current
(or its reverse). 10% ~ 90% of output voltage
*3
For AC mode, at an output voltage of 100 V / 200 V, maximum current, and
load power factor of 1 and sine wave only.
Model
ASR-2050
ASR-2050R
ASR-2100
ASR-2100R
Measured value display
Note: All accuracy of the measurement function is indicated for 23 °C±5 °C.
Voltage RMS, AVG
value
*1
Resolution 0.1 V
Accuracy
*2
For 45 Hz to 65 Hz and DC: ±(0.5 % of
r 0.3 V / 0.6 V)
For 40 Hz to 999.9 Hz: ±(0.7 % of r
0.9 V / 1.8 V)
PEAK value Resolution 0.1 V
Accuracy
For 45 Hz to 65 Hz and DC: ±(|2 % of
reading| + 1 V / 2 V)
Current RMS, AVG
value
Resolution 0.01 A
Accuracy
*3
For 45 Hz to 65 Hz
and DC:
±(0.5 % of r
0.02 A / 0.02 A)
For 40 Hz to 999.9
Hz:
±(0.7 % of r
0.04 A / 0.04 A)
For 45 Hz to 65 Hz
and DC:
±(0.5 % of r
0.04 A / 0.02 A)
For 40 Hz to 999.9
Hz:
±(0.7 % of r
0.08 A / 0.04 A)
PEAK value Resolution 0.01 A
Accuracy*4 For 45 Hz to 65 Hz
and DC:
±(|2 % of reading| +
0.2 A / 0.1 A)
For 45 Hz to 65 Hz
and DC:
±(|2 % of reading| +
0.2 A / 0.1 A)
Summary of Contents for ASR-2000 Series
Page 1: ...Programmable AC DC Power Source ASR 2000 Series USER MANUAL ISO 9001 CERTIFIED MANUFACTURER ...
Page 11: ...GETTING STARTED 11 ...
Page 130: ...ASR 2000 Series User Manual 130 Example Power ON setting ...
Page 216: ...ASR 2000 Series User Manual 216 ASR 2000 Dimensions ASR 2100 2050 Scale mm ...
Page 217: ...APPENDIX 217 ASR 2100R 2050R Scale mm ...
Page 218: ...ASR 2000 Series User Manual 218 ASR 2100R 2050R with GET Series Box Scale mm ...
Page 219: ...APPENDIX 219 GET 003 Series Box GET 004 Series Box ...