MISCELLANEOUS
139
External Control
User can enable or disable the External Control I/O input. When
External Control I/O input is set as disabled, the ASR-2000 series
status will remain output.
Steps
1.
Press the
Menu
key. The Menu
setting will appear on the display.
2.
Use the scroll wheel to go to item 2,
MISC
Configuration
and press
Enter
.
3.
Go to the
External Control
setting using the scroll
wheel and press
Enter
. Enable or disable External
Control I/O and press
Enter
again to confirm
selection.
ON
Signal will be input from the pin 12
to the pin 18 of External Control
I/O, and ASR-2000 series is able to
receive external input signal and
execute control action.
OFF
Signal will be input from the pin 11
to the pin 18 of External Control
I/O, and ASR-2000 series is Not
able to receive external input signal.
Example
External Control setting