2.
Set ACV/DCV/GAIN value with the scroll
wheel or with the F1 ~ F4 soft-keys.
AC+DC-INT, AC-INT, DC-INT
ACV
DCV
Range
0 volts ~ full range
Soft-keys
DEF1, DEF2, MAX, MIN
AC+DC-EXT, AC-EXT, AC-VCA
GAIN
Range
0 times ~ full range
Soft-keys
DEF1, DEF2, MAX, MIN
AC+DC-ADD, AC-ADD
ACV
DCV
Range
0 volts ~ full range
Soft-keys
DEF1, DEF2, MAX, MIN
GAIN
Range
0 times ~ full range
Soft-keys
DEF1, DEF2, MAX, MIN
AC+DC-Sync, AC-Sync
ACV
DCV
Range
0 volts ~ full range
Soft-keys
DEF1, DEF2, MAX, MIN
3.
Press
Enter
to confirm voltage or gain setting.
Defined Settings
The DEF1 and DEF2 settings are user-defined
settings. By default they are set to 0.0 and 100.0
volts (100V range), 200.0 volts (200V and AUTO
range), respectively and 100 and 200 times for
gain. The MAX and MIN soft-keys set voltage or
gain parameters to the maximum or minimum
value, respectively.
4.
Repeat the previous steps 1 ~ 2 to set AC/DC
voltage and gain value with the scroll wheel.