TEST MODE FUNCTION
145
Branch1/
Branch2
The Branch settings allow you to
make a selectable branch within the
sequence when the sequence is
running or on hold. The branch1 or
branch2 actions are enabled by
pressing the
F1
or
F2
function keys,
or by using the :TRIG:SEQ:SEL:EXEC
remote control command. After the
branch step(s) have completed the
unit will return back to the step from
which the branch was executed and
continue to run the step from where
it left off.
Term
(Termination)
Determines the step termination
settings at end of the step.
The CONTI setting tells the sequence
to go to the next step.
The HOLD setting will pause the
output at the end of the step and will
only continue to the next step when
CONTI [F3] is pressed.
The END setting will end the
sequence and go to Step 0(standby
step).
Sync Code
Sets the synchronous code including
LL, LH, HL and HH for each step.
ON/OFF Phs
Sets the start and stop phase of the
AC waveform for each step. The ON
Phs setting sets the starting phase
of
the step
.
OFF Phs sets the off phase
for the
output
when the output if turned off.
Note
It is available for AC+DC-INT and AC-INT modes only.
Summary of Contents for ASR-2000 Series
Page 1: ...Programmable AC DC Power Source ASR 2000 Series USER MANUAL ISO 9001 CERTIFIED MANUFACTURER ...
Page 11: ...GETTING STARTED 11 ...
Page 130: ...ASR 2000 Series User Manual 130 Example Power ON setting ...
Page 216: ...ASR 2000 Series User Manual 216 ASR 2000 Dimensions ASR 2100 2050 Scale mm ...
Page 217: ...APPENDIX 217 ASR 2100R 2050R Scale mm ...
Page 218: ...ASR 2000 Series User Manual 218 ASR 2100R 2050R with GET Series Box Scale mm ...
Page 219: ...APPENDIX 219 GET 003 Series Box GET 004 Series Box ...