ASR-2000 Series User Manual
26
Equation:
Maximum Peak
Current (AC-INT
mode only)
The maximum value of the output current (peak
value) will be provided consecutively to a capacitor
input-type rectifying load when the following
situations exist:
Output voltage is 100 to 175 V within the 100 V
range.
Output voltage is 200 to 350 V within the 200 V
range.
Output frequency is 40 to 999.9 Hz in AC mode,
and 1 to 999.9 Hz in AC+DC mode.
Note
Rated maximum current (rms value) x 4 is equal to
maximum peak current
Power Factor (PF)
The power factor, which stands for a ratio of the
active power correlated to the apparent power,
indicates degradation level within efficiency that
results from the phase difference between AC
current and AC voltage.
Equation: