PREPARING FOR MEASUREMENT
10.5.1 Testing Proper Functioning of Force Sensor
Z
Check the force sensor with a reference weight.
Fig. 12: Reference weight
1
►
Place CoboSafe-CBSF on a flat surface. The measuring surface must face up.
2
►
Carefully lower the reference weight onto the measuring surface and wait until the
measurement begins.
Measurement start
Measurement starts at 20 N!
The measurement is running. After 5 seconds, the measurement result can be transferred to
CoboSafe-Vision and displayed. If the measured force corresponds to the weight force of the
reference weight applied, the force sensor functions as intended. If the measured value devia-
tes, the force sensor is damaged.
The CoboSafe CBSF has been tested to confirm proper functioning.
Damaged force sensor
A damaged force sensor must not be used for measurement and must be replaced.