76 Smart Climate 310 rev. 03
The controller then waits for the
Wind Effect Delay
once again. If
the pressure level is still out of range afterwards, the SP
compensation is applied once more. This cycle is repeated up until
the pressure gets back to the normal range.
The cycle may be repeated as needed or up to four consecutive
times, depending on the settings. When the pressure level gets
back to the normal range [
points B & D
on the graphic], the inlet
keeps its compensated position.
Viewing the Static Pressure Level
1. Press
Current Conditions
.
2. Press the current condition
down-arrow key in order to
reach the static pressure display.
Accessible if the static pressure sensor is enabled in the USER
SETUP.
3. Press the navigation
down-arrow key once. Today's
minimum static pressure reading is displayed, along with
the time and date.
4. Press the navigation
down-arrow key once again. Today's
maximum static pressure reading is displayed, along with
the time and date.
5. Keep pressing the navigation
down-arrow key to display
minimum and maximum pressure readings of the 6 last
days.
6. Use the up-arrow key to return to previous screen displays.
Summary of Contents for Smart Climate 310
Page 1: ...Smart Climate 310 User s Guide 895 00676 REV 04 890 00582 REV 03...
Page 96: ...96 Smart Climate 310 rev 03 Probe Assignment...
Page 97: ...Smart Climate 310 rev 03 97 User Setup Menu...
Page 98: ...98 Smart Climate 310 rev 03...
Page 101: ...Smart Climate 310 rev 03 101 3 Press on the card and make it clip to the main board...
Page 102: ...102 Smart Climate 310 rev 03...