![GSi Smart Climate 310 User Manual Download Page 61](http://html1.mh-extra.com/html/gsi/smart-climate-310/smart-climate-310_user-manual_2274990061.webp)
Smart Climate 310 rev. 03 61
14. Follow the same procedure to set the start/stop
temperatures and the On and Off times of the second
timer.
15. Repeat for all heating stages in use.
0-10V Heating Output
The 0-10V output of the controller can be used to control heating
units. Refer to the USER SETUP section to enable a 0-10V heating
output.
When the room temperature decreases:
Above the Stop at T°:
The output is disabled;
Below the Minimum T°
: The 0-10V heating output is runs at
minimum intensity. The heat level increases as the temperature
decreases;
At the Maximum T°:
The 0-10V heating output reaches its
maximum intensity.