![GSi Smart Climate 310 User Manual Download Page 18](http://html1.mh-extra.com/html/gsi/smart-climate-310/smart-climate-310_user-manual_2274990018.webp)
18 Smart Climate 310 rev. 03
Number of Temperature Sensors in the Room
Select the number of temperature sensors connected to the
controller (1 to 4 sensors).
Room Probes
Select the room sensors that are used to be part of the average
room temperature.
NOTE:
Blinking digits represent probes that are selected to be
part of the average room temperature. At least one temperature
probe must be selected.
Use Water Meter
Select
Yes
if a water meter is connected to the controller.
Water Meter Units
Select the water units: Gallons or liters.
Accessible if the water meter is enabled above.
Water Meter Calibration
Set the number of gallons or liters per pulse. The value can vary
between 0.1 and 10. The default value is 1.0 Unit/pulse.
Accessible if the water meter is enabled above.
Use Humidity Sensor
Select
Yes
if a relative humidity sensor is connected to the
controller.
Relative Humidity (RH) Compensation
Enable the desired RH compensation method
Min Vent/Heater
or
select
None
to disable the RH compensation functions.
Available if the humidity sensor is enabled above.
Use Outside Temperature Probe
Select
Yes
if an outside temperature sensor is connected to the
controller.
Outside T° Compensation on differentials
Select
Yes
for the controller to adjust the variable stage bandwidth
as a function of the outside
Accessible if the outside temperature sensor is enabled above.
Summary of Contents for Smart Climate 310
Page 1: ...Smart Climate 310 User s Guide 895 00676 REV 04 890 00582 REV 03...
Page 96: ...96 Smart Climate 310 rev 03 Probe Assignment...
Page 97: ...Smart Climate 310 rev 03 97 User Setup Menu...
Page 98: ...98 Smart Climate 310 rev 03...
Page 101: ...Smart Climate 310 rev 03 101 3 Press on the card and make it clip to the main board...
Page 102: ...102 Smart Climate 310 rev 03...