Setting Start and Stop Temperatures for
Timers 1 & 2
Start and stop temperatures of both mist timers are directly related
to the set point. This means that when the main set point changes,
the start and stop temperatures are adjusted by the same amount.
The start temperature of the first mist timer can be adjusted from -
40°F to 40°F (-22.2°C to 22.2°C) from the set point; the stop
temperature can be adjusted from 0.5°F to 40°F (0.3°C to 22.2°C)
below its start temperature.
The start temperature of the second mist timer can be adjusted
from 0.5°F to 40°F (0.3°C to 22.2°C) above the start temperature
of the first timer; the stop temperature can be adjusted from 0.5 °F
to 40°F (0.3°C to 22.2°C) below its start temperature.
To set the start and stop temperatures for timers 1 and 2, proceed
as follows:
1. Press
Mist
. The start temperature of the first mist timer
is displayed.
Accessible if mist units are enabled in the USER SETUP.
2. Press
Adjust
then use the arrow keys to set the start
temperature of the first timer to the desired value.
3. Press
Adjust
again to validate.
4. Press the down-arrow key. The stop temperature of
the first timer is displayed.
5. Press
Adjust
then use the arrow keys to set the stop
temperature of the first timer to the desired value.
6. Press
Adjust
again to validate.
7. Press the down-arrow key twice. The start temperature
of the second mist timer is displayed.
8. Repeat steps 1 to 7 to set the start and stop
temperatures of the second mist timer.
Summary of Contents for Smart Climate 310
Page 1: ...Smart Climate 310 User s Guide 895 00676 REV 04 890 00582 REV 03...
Page 96: ...96 Smart Climate 310 rev 03 Probe Assignment...
Page 97: ...Smart Climate 310 rev 03 97 User Setup Menu...
Page 98: ...98 Smart Climate 310 rev 03...
Page 101: ...Smart Climate 310 rev 03 101 3 Press on the card and make it clip to the main board...
Page 102: ...102 Smart Climate 310 rev 03...