DC INVERTER MULTI VRF PRODUCT
2
PRODUCT
1 MODELS LIST
1.1 Outdoor Unit
Capacity
Units
Series
Model
Cooling
(Btu/h)
Heating
(Btu/h)
Ref.
Power
Supply
Appearance
GMV(L)-Pd100W/NaB-K
34120
37532
R410A
220-240V
~50Hz
GMV(L)-Pd120W/NaB-K
40944
47768
R410A
220-240V
~50Hz
GMV(L)-Pd140W/NaB-K
47768
52545
R410A
220-240V
~50Hz
DC
Inverter
Multi VRF
GMV(L)-Pd160W/NaB-K
54592
60051
R410A
220-240V
~50Hz
Note:1Ton =12000Btu/h = 3.517kW
Notes: a. Cooling only unit (GMVL type) has no items on heating;
b. Noise was tested in semi-silenced room, so the actual noise value will be a little higher for change of ambient;
c. The charge amount of R410A in the list is only the sealed amount when outdoor unit outgoing. When installing,
calculate the additional charge amount according to actual length of pipe and the matched indoor units;
d. Nominal capacities are based on the following conditions:
Cooling
Heating
Indoor :27
℃
(80.6
℉
)/19
℃
(66.2
℉
)
Outdoor: 35
℃
(95
℉
)/-
Indoor: 20
℃
(68
℉
)/-
Outdoor : 7
℃
(44.6
℉
)/6
℃
(42.8
℉
);
Summary of Contents for GMV(L)-Pd100W/NaB-K
Page 1: ...1 DC INVERTER MULTI VRF Service Manual GREE ELECTRIC APPLIANCES INC OF ZHUHAI ...
Page 4: ...GREE COMMERCIAL AIR CONDITIONER DC INVERTER MULTI VRF 1 PRODUCT ...
Page 40: ...GREE COMMERCIAL AIR CONDITIONER DC INVERTER MULTI VRF 37 CONTROL ...
Page 41: ...DC INVERTER MULTI VRF CONTROL 38 CONTROL 1 OPERATION FLOWCHART ...
Page 43: ...DC INVERTER MULTI VRF CONTROL 40 1 2 Heating Operation ...
Page 70: ...DC INVERTER MULTI VRF CONTROL 67 2 Frame Diagram of System Net 上 WC ...
Page 90: ...GREE COMMERCIAL AIR CONDITIONER DC INVERTER MULTI VRF 87 INSTALLATION ...
Page 115: ...DC INVERTER MULTI VRF INSTALLATION 112 ...
Page 159: ...DC INVERTER MULTI VRF MAINTENANCE 156 MAINTENANCE ...
Page 179: ...DC INVERTER MULTI VRF MAINTENANCE 176 ...
Page 212: ...DC INVERTER MULTI VRF MAINTENANCE 209 2 GMV L R90T Na K GMV L R112T Na K GMV L R125T Na K ...
Page 216: ...DC INVERTER MULTI VRF MAINTENANCE 213 2 GMV L R40P Na K GMV L R45P Na K GMV L R50P Na K ...
Page 224: ...DC INVERTER MULTI VRF MAINTENANCE 221 2 GMV L R36G NaB K GMV L R45G NaB K ...
Page 226: ...DC INVERTER MULTI VRF MAINTENANCE 223 3 GMV L R50G NaB K GMV L R56G NaB K ...
Page 228: ...DC INVERTER MULTI VRF MAINTENANCE 225 4 GMV L R71G Na K GMV L R80G Na K ...
Page 230: ...DC INVERTER MULTI VRF MAINTENANCE 227 5 GMV L R22G NaC K GMV L R28G NaC K ...
Page 232: ...DC INVERTER MULTI VRF MAINTENANCE 229 6 GMV L R36G NaC K GMV L R45G NaC K ...
Page 237: ...DC INVERTER MULTI VRF MAINTENANCE 234 2 GMV L R71Zd Na K ...
Page 240: ...DC INVERTER MULTI VRF MAINTENANCE 237 3 GMV L R90Zd Na K GMV L R112Zd Na K GMV L R125Zd Na K ...