DC INVERTER MULTI VRF PRODUCT
24
Model
GMV(L)-R50T/Na-K
GMV(L)-R56T/Na-K
GMV(L)-R63T/Na-K
kW
5.0
5.6
6.3
Cooling Capacity
Btu
17060
19100
21500
kW
5.8
6.3
7.0
Heating Capacity
Btu
19790
21500
23890
m3/h
680
1180
1180
Air Flow Rate
CFM
400
695
695
Sound Pressure Level (H/L)
dB(A)
37/34
39/35
39/35
External Static Pressure
Pa
0
0
0
Power Supply
220-240V
~
50Hz
220-240V
~
50Hz
220-240V
~
50Hz
Output
kW
0.035
0.035
0.035
Fan Motor
Running
Current
A
0.28
0.37
0.37
mm
Φ
12.7
Φ
15.9
Φ
15.9
Gas Pipe
inch
1/2
"
5/8
"
5/8
"
mm
Φ
6.35
Φ
9.52
Φ
9.52
Liquid Pipe
inch
1/4
"
3/8
"
3/8
"
Connecting
Pipes
Connection Method
Flare Connection
Flare Connection
Flare Connection
Drain Pipes
(External Dia. × Thickness)
mm
Φ
30
×
1.5
Φ
30
×
1.5
Φ
30
×
1.5
Unit Dimensions
(W×D×H)
mm
Main body
:
840
×
840
×
190
Panel
:
950
×
950
×
60
Main body
:
840
×
840
×
240
Panel
:
950
×
950
×
60
Package Dimensions
(W×D×H)
mm
Main body
:
960
×
960
×
257
Panel
:
1040
×
1025
×
115
Main body
:
960
×
960
×
310
Panel
:
1040
×
1025
×
115
Net Weight
(Main body/Panel)
kg
25/6.5
30/6.5
Gross Weight
(Main body/Panel)
kg
33/10
38/10
Notes:
①
Refer to the product nameplate for parameters and specification of the unit;
②
The model with GMVL code is cooling only unit; while the model with GMV code is heat pump unit; the cooling only
units dose not have any parameters of performing heating;
③
The sound level was tested under circumstance of semi-anechoic chamber; the value of noise could be a little higher in
actual operation.
Summary of Contents for GMV(L)-Pd100W/NaB-K
Page 1: ...1 DC INVERTER MULTI VRF Service Manual GREE ELECTRIC APPLIANCES INC OF ZHUHAI ...
Page 4: ...GREE COMMERCIAL AIR CONDITIONER DC INVERTER MULTI VRF 1 PRODUCT ...
Page 40: ...GREE COMMERCIAL AIR CONDITIONER DC INVERTER MULTI VRF 37 CONTROL ...
Page 41: ...DC INVERTER MULTI VRF CONTROL 38 CONTROL 1 OPERATION FLOWCHART ...
Page 43: ...DC INVERTER MULTI VRF CONTROL 40 1 2 Heating Operation ...
Page 70: ...DC INVERTER MULTI VRF CONTROL 67 2 Frame Diagram of System Net 上 WC ...
Page 90: ...GREE COMMERCIAL AIR CONDITIONER DC INVERTER MULTI VRF 87 INSTALLATION ...
Page 115: ...DC INVERTER MULTI VRF INSTALLATION 112 ...
Page 159: ...DC INVERTER MULTI VRF MAINTENANCE 156 MAINTENANCE ...
Page 179: ...DC INVERTER MULTI VRF MAINTENANCE 176 ...
Page 212: ...DC INVERTER MULTI VRF MAINTENANCE 209 2 GMV L R90T Na K GMV L R112T Na K GMV L R125T Na K ...
Page 216: ...DC INVERTER MULTI VRF MAINTENANCE 213 2 GMV L R40P Na K GMV L R45P Na K GMV L R50P Na K ...
Page 224: ...DC INVERTER MULTI VRF MAINTENANCE 221 2 GMV L R36G NaB K GMV L R45G NaB K ...
Page 226: ...DC INVERTER MULTI VRF MAINTENANCE 223 3 GMV L R50G NaB K GMV L R56G NaB K ...
Page 228: ...DC INVERTER MULTI VRF MAINTENANCE 225 4 GMV L R71G Na K GMV L R80G Na K ...
Page 230: ...DC INVERTER MULTI VRF MAINTENANCE 227 5 GMV L R22G NaC K GMV L R28G NaC K ...
Page 232: ...DC INVERTER MULTI VRF MAINTENANCE 229 6 GMV L R36G NaC K GMV L R45G NaC K ...
Page 237: ...DC INVERTER MULTI VRF MAINTENANCE 234 2 GMV L R71Zd Na K ...
Page 240: ...DC INVERTER MULTI VRF MAINTENANCE 237 3 GMV L R90Zd Na K GMV L R112Zd Na K GMV L R125Zd Na K ...