DC INVERTER MULTI VRF PRODUCT
20
Model
GMV(L)-R56P/NaB-K
GMV(L)-R71P/NaB-K
GMV(L)-R90P/NaB-K
kW
5.6
7.1
9.0
Cooling Capacity
Btu
19108
24226
30709
kW
6.3
8.0
10.0
Heating Capacity
Btu
21496
27296
34120
m3/h
1400
1400
2000
Air Flow Rate
CFM
824
824
1177
Sound Pressure Level (H/L)
dB(A)
42/38
42/38
44/40
External Static Pressure
Pa
60/30
60/30
80/40
Power Supply
220-240V
~
50Hz
220-240V
~
50Hz
220-240V
~
50Hz
Output
kW
0.24
0.24
0.36
Fan Motor
Running Current
A
1.00
1.00
1.60
mm
Φ
15.9
Φ
15.9
Φ
15.9
Gas Pipe
inch
5/8
"
5/8
"
5/8
"
mm
Φ
9.52
Φ
9.52
Φ
9.52
Liquid Pipe
inch
3/8
"
3/8
"
3/8
"
Connecting
Pipes
Connection Method
Flare Connection
Flare Connection
Flare Connection
Drain Pipes
(
External Dia. × Thickness
)
mm
Φ
30×1.5
Φ
30×1.5
Φ
30×1.5
Unit Dimensions
(W×D×H)
mm
1112×756×300
1112×756×300
1425×756×300
Package Dimensions
(W×D×H)
mm
1245×785×360
1245×785×360
1514×785×360
Weight
(
Net/Gross
)
kg
49/56
49/56
62/71
Notes:
①
Refer to the product nameplate for parameters and specification of the unit;
②
The model with GMVL code is cooling only unit; while the model with GMV code is heat pump unit; the cooling only
units dose not have any parameters of performing heating;
③
The sound level was tested under circumstance of semi-anechoic chamber; the value of noise could be a little higher in
actual operation.
Summary of Contents for GMV(L)-Pd100W/NaB-K
Page 1: ...1 DC INVERTER MULTI VRF Service Manual GREE ELECTRIC APPLIANCES INC OF ZHUHAI ...
Page 4: ...GREE COMMERCIAL AIR CONDITIONER DC INVERTER MULTI VRF 1 PRODUCT ...
Page 40: ...GREE COMMERCIAL AIR CONDITIONER DC INVERTER MULTI VRF 37 CONTROL ...
Page 41: ...DC INVERTER MULTI VRF CONTROL 38 CONTROL 1 OPERATION FLOWCHART ...
Page 43: ...DC INVERTER MULTI VRF CONTROL 40 1 2 Heating Operation ...
Page 70: ...DC INVERTER MULTI VRF CONTROL 67 2 Frame Diagram of System Net 上 WC ...
Page 90: ...GREE COMMERCIAL AIR CONDITIONER DC INVERTER MULTI VRF 87 INSTALLATION ...
Page 115: ...DC INVERTER MULTI VRF INSTALLATION 112 ...
Page 159: ...DC INVERTER MULTI VRF MAINTENANCE 156 MAINTENANCE ...
Page 179: ...DC INVERTER MULTI VRF MAINTENANCE 176 ...
Page 212: ...DC INVERTER MULTI VRF MAINTENANCE 209 2 GMV L R90T Na K GMV L R112T Na K GMV L R125T Na K ...
Page 216: ...DC INVERTER MULTI VRF MAINTENANCE 213 2 GMV L R40P Na K GMV L R45P Na K GMV L R50P Na K ...
Page 224: ...DC INVERTER MULTI VRF MAINTENANCE 221 2 GMV L R36G NaB K GMV L R45G NaB K ...
Page 226: ...DC INVERTER MULTI VRF MAINTENANCE 223 3 GMV L R50G NaB K GMV L R56G NaB K ...
Page 228: ...DC INVERTER MULTI VRF MAINTENANCE 225 4 GMV L R71G Na K GMV L R80G Na K ...
Page 230: ...DC INVERTER MULTI VRF MAINTENANCE 227 5 GMV L R22G NaC K GMV L R28G NaC K ...
Page 232: ...DC INVERTER MULTI VRF MAINTENANCE 229 6 GMV L R36G NaC K GMV L R45G NaC K ...
Page 237: ...DC INVERTER MULTI VRF MAINTENANCE 234 2 GMV L R71Zd Na K ...
Page 240: ...DC INVERTER MULTI VRF MAINTENANCE 237 3 GMV L R90Zd Na K GMV L R112Zd Na K GMV L R125Zd Na K ...