DC INVERTER MULTI VRF PRODUCT
28
4.2.3 Wall mounted Type
Model
GMV(L)-R22G/NaG-K
GMV(L)-R28G/NaG-K
GMV(L)-R36G/NaG-K
kW
2.2
2.8
3.6
Cooling Capacity
Btu
7507
9554
12284
kW
2.5
3.2
4.0
Heating Capacity
Btu
8530
10919
13649
m3/h
360
360
500
Air Flow Rate
CFM
212
212
294
Sound Pressure Level
(H/L)
dB(A)
30/28
30/28
36/28
External Static Pressure
Pa
0
0
0
Power Supply
220-240V~50Hz
220-240V~50Hz
220-240V~50Hz
Output
kW
0.014
0.014
0.022
Fan Motor
Running
Current
A
0.15
0.15
0.22
mm
Φ
9.52
Φ
9.52
Φ
12.7
Gas Pipe
inch
3/8
"
3/8
"
1/2
"
mm
Φ
6.35
Φ
6.35
Φ
6.35
Liquid Pipe
inch
1/4
"
1/4
"
1/4
"
Connecting
Pipes
Connection Method
Flare Connection
Flare Connection
Flare Connection
Drain Pipes
(External Dia. ×Thickness)
mm
Φ
20×1.5
Φ
20×1.5
Φ
20×1.5
Unit Dimensions
(W×D×H)
mm
830×189×285
830×189×285
830×189×285
Package Dimensions
(W×D×H)
mm
995×394×268
995×394×268
995×394×268
Weight
(
Net/Gross
)
kg
8/14.3
8/14.3
11/15.8
Notes:
①
Refer to the product nameplate for parameters and specification of the unit;
②
The model with GMVL code is cooling only unit; while the model with GMV code is heat pump unit; the cooling only
units dose not have any parameters of performing heating;
③
The sound level was tested under circumstance of semi-anechoic chamber; the value of noise could be a little higher in
actual operation.
Summary of Contents for GMV(L)-Pd100W/NaB-K
Page 1: ...1 DC INVERTER MULTI VRF Service Manual GREE ELECTRIC APPLIANCES INC OF ZHUHAI ...
Page 4: ...GREE COMMERCIAL AIR CONDITIONER DC INVERTER MULTI VRF 1 PRODUCT ...
Page 40: ...GREE COMMERCIAL AIR CONDITIONER DC INVERTER MULTI VRF 37 CONTROL ...
Page 41: ...DC INVERTER MULTI VRF CONTROL 38 CONTROL 1 OPERATION FLOWCHART ...
Page 43: ...DC INVERTER MULTI VRF CONTROL 40 1 2 Heating Operation ...
Page 70: ...DC INVERTER MULTI VRF CONTROL 67 2 Frame Diagram of System Net 上 WC ...
Page 90: ...GREE COMMERCIAL AIR CONDITIONER DC INVERTER MULTI VRF 87 INSTALLATION ...
Page 115: ...DC INVERTER MULTI VRF INSTALLATION 112 ...
Page 159: ...DC INVERTER MULTI VRF MAINTENANCE 156 MAINTENANCE ...
Page 179: ...DC INVERTER MULTI VRF MAINTENANCE 176 ...
Page 212: ...DC INVERTER MULTI VRF MAINTENANCE 209 2 GMV L R90T Na K GMV L R112T Na K GMV L R125T Na K ...
Page 216: ...DC INVERTER MULTI VRF MAINTENANCE 213 2 GMV L R40P Na K GMV L R45P Na K GMV L R50P Na K ...
Page 224: ...DC INVERTER MULTI VRF MAINTENANCE 221 2 GMV L R36G NaB K GMV L R45G NaB K ...
Page 226: ...DC INVERTER MULTI VRF MAINTENANCE 223 3 GMV L R50G NaB K GMV L R56G NaB K ...
Page 228: ...DC INVERTER MULTI VRF MAINTENANCE 225 4 GMV L R71G Na K GMV L R80G Na K ...
Page 230: ...DC INVERTER MULTI VRF MAINTENANCE 227 5 GMV L R22G NaC K GMV L R28G NaC K ...
Page 232: ...DC INVERTER MULTI VRF MAINTENANCE 229 6 GMV L R36G NaC K GMV L R45G NaC K ...
Page 237: ...DC INVERTER MULTI VRF MAINTENANCE 234 2 GMV L R71Zd Na K ...
Page 240: ...DC INVERTER MULTI VRF MAINTENANCE 237 3 GMV L R90Zd Na K GMV L R112Zd Na K GMV L R125Zd Na K ...