GKP-2302 User Manual
54
2.
Set the values in the [Freq Up]/[Freq Lo] items so that the upper value of the frequency
setting range limit is higher than or equal to the lower limit.
3.
Close the window.
4.1.5
About the Wattage Limiter
The wattage limiter operates when trying to output power exceeding the rated power. When
the wattage limiter operates, the output voltage is suppressed until the active power per phase
is equal the value shown in Table 4-1 (reference value). While the limiter is working, the
icon is displayed and LIMIT LED illuminates.
Table 4-1 Wattage Limiter Value per Phase (Reference value)
Rated output
Per phase(kVA)
Wattage limiter value
(W)
N
um
be
r
o
f
p
ow
er
un
it
s
P
er
p
h
as
e
1
1.5
k
VA
1575
2
3
k
VA
3150
--------
Notes
----------------------------------------------------------------------------------------------------------------
If the wattage limiter operates, suppress the output wattage to within the rated output
power by lowering the output voltage setting value.
Active power (unit: W) is restricted by the wattage limiter, however, reactive power (unit:
var) is not restricted. Therefore, the apparent power (unit: VA) may exceed the rated
power depending on the power factor of the load. Set the output voltage so that the
apparent power does not exceed the rated power, regardless of the operation of the
wattage limiter.
The value of the wattage limiter cannot be changed. To limit the output power to a value
that is lower than the rating, decrease the number of power units that are energized
through the power unit energization setting, or use the peak current limiter or the RMS
current limiter.
---------------------------------------------------------------------------------------------------------------------------------
Summary of Contents for GKP-2302
Page 15: ...1 1 OUTLINE 1 1 Overview 2 1 2 Features 2...
Page 28: ...GKP 2302 User Manual 14 Nothing is connected to the output terminal...
Page 60: ......
Page 186: ......
Page 187: ...173 5 DESCRIPTION OF SCREEN AND MENU 5 1 Screen Configuration 174 5 2 Menu Composition 177...
Page 195: ...181 6 REMOTE CONTROL 6 1 Communication Interface 182 6 2 Remote Local State Switching 188...
Page 216: ......
Page 222: ......