3.4 Using the Continuous Function
39
Item
Description
Unit
V
Output voltage, effective
value
The effective (RMS) value of the output
voltage on the output terminal.
Vrms
Vavg
Output voltage, average
value
The average DC value of the output
voltage on the output terminal.
V
Vmax
Output voltage,
maximum peak value
The maximum peak value of the output
voltage on the output terminal.
Vpk
Vmin
Output voltage,
minimum peak value
The minimum peak value of the output
voltage on the output terminal.
Vpk
I
Output RMS current
The effective (RMS) value of the output
current.
Arms
Iavg
Output current, average
value
The average DC value of the output
current.
A
Imax
Output current,
maximum peak value
The maximum peak value of the output
current.
Apk
Imin
The minimum peak value
of the output current
The minimum peak value of the output
current.
Apk
Ipk-Hold
Output current,
peak-hold value
The hold value of Imax or Imin, either
of which value is bigger.
Apk
P
Active power
The active power provided to the load.
The power of the phase is displayed
when in the phase voltage display. The
total power is displayed when in the
line voltage display.
W
S
Apparent power
The apparent power provided to the
load.
The power of the phase is displayed
when in the phase voltage display. The
total power is displayed when in the
line voltage display.
VA
Q
Reactive power
The reactive power provided to the
load.
The power of the phase is displayed
when in the phase voltage display. The
total power is displayed when in the
line voltage display.
var
PF
Power factor
The power factor of the load.
—
CF
Crest factor
The crest factor of the output current
(peak value/effective value).
—
F
Synchronization
frequency
The measured frequency value of the
synchronization signal source when the
signal source is SYNC.
Hz
3.4.9
Switching the Display Format (RMS/AVG/Peak) of the Measured Value
You can switch the display format of the measured value (RMS/AVG/Peak) for the output
voltage and output current. The items which are displayed in each measuring mode are shown
in Table 3-12.
Table 3-12 The Measuring Mode for the Measured Values of the Output Voltage and Output Current
Summary of Contents for GKP-2302
Page 15: ...1 1 OUTLINE 1 1 Overview 2 1 2 Features 2...
Page 28: ...GKP 2302 User Manual 14 Nothing is connected to the output terminal...
Page 60: ......
Page 186: ......
Page 187: ...173 5 DESCRIPTION OF SCREEN AND MENU 5 1 Screen Configuration 174 5 2 Menu Composition 177...
Page 195: ...181 6 REMOTE CONTROL 6 1 Communication Interface 182 6 2 Remote Local State Switching 188...
Page 216: ......
Page 222: ......