![Goldschmidt SMARTWELD SPARK Operation Manual Download Page 49](http://html.mh-extra.com/html/goldschmidt/smartweld-spark/smartweld-spark_operation-manual_2241103049.webp)
49
FR
AN
Ç
AI
S
EN
G
LISH
D
EU
TS
C
H
ON-LED
Comes on green when the device is
switched on.
8.4 Acoustic signal at ignition
An acoustic signal (105 dB) sounds as soon as the Thermit
®
portion in the crucible
is ignited. The acoustic signal tells the operator to remove the device from the
crucible and get to a safe distance as fast as possible (away from the crucible).
The acoustic signal indicates that the
Thermit
®
portion has
definitely ignited even if a reaction isn’t immediately apparent!
9 Use
9.1 Checking the device before the use
Prior to putting the device into service, check if the travel case contains all com-
ponents included in the scope of delivery.
Then check the device for external damage. Pay particular attention to the plug
connection for the extension adapter. Make sure that the device and the compo-
nent parts are in their correct working conditions. If not, do not use them.
If you discover damage to the buttons, switches, pilot lamps,
or other important components, do not use the device.
Immediately contact the manufacturer’s customer service.
Never attempt to repair the device yourself.
49