This section of the manual is an introduction to MotionMaestro’s
©
features that are required for installa-
tion and setup of the Omega series amplifiers. Only those features of MotionMaestro
©
required for de-
fining motor characteristics are covered. This is not meant to be a step by step tutorial. The “System
setup” section is intended as a tutorial for motor setup. You may need to refer to this section when set-
ting up a motor. The following features are reviewed here:
1. Opening of communications.
2. Model Information.
3. Digital I/O setup.
4. Amplifier mode setup.
5. Commutation setup.
6. Encoder setup.
7. Oscilloscope
8. Terminal Window
9. Motor Parameters.
10. Motor Safety.
11. Amplifier Status.
12. Control Panel.
13. Saving parameters.
14. Backing up a copy of amplifier parameters.
Opening of Communications
Before MotionMaestro
©
can be used, communications must be established between the amplifier and
the PC that MotionMaestro
©
is running on. Before opening communications in MotionMaestro
©,
you
must have a serial communications cable wired as described in the hardware section of this manual.
This can be a RS-232 or RS-485/422 wiring. You may also need to set the serial port on your com-
puter as described in the system setup
section.
Open communications by selecting the
“Open” option on MotionMaestro’s
©
main menu tool bar.
Select the COM port that you con-
nected the serial port cable to and en-
sure that a baud rate of 115200 is se-
lected. When you press OK Motion-
Maestro
©
will query the amplifier to de-
termine what amplifier model is con-
nected. If communications is estab-
lished, you should see a screen similar
to the following with all green communi-
cations status indicators.
When communications cannot be
opened, a dialog is presented indicating
so. If you cannot open communications
please check your cable, PC COM port
settings and power to the amplifier.
Open Communications dialog box