Analog output
ANALOG OUT is a user selectable analog output. The output ranges from -10 volts to +10 volts and
has an 8 bit (256 step) resolution.
The analog output can be used to monitor amplifier signals at the servo update frequency. By doing
so, the application engineer can determine the amplifier’s true response to commanded signals. The
analog output is for
reference use only. It is not intended for control purposes. At power on, its value
is undetermined until the power on reset has completed. During some amplifier functions, this output is
temporarily disabled. These functions include saving and recalling parameters from non-volatile mem-
ory. The output is filtered to minimize the switching noise from the PWM amplifier. The analog output
is updated once per PWM cycle.
Analog Out source select
Software