Glentek Inc. 208 Standard Street, El Segundo, California 90245, U.S.A. (310) 322-3026
31
Reading Amp Fault Data by Using Direct Command
Note: This example demonstrates how to read amp faults .
1. “0x08”: Fault Read (per page 34)
2. “0x00000860”: hex decimal number for 100001100000 (bin.)
3. Bit 5 (100001
1
00000): Invalid Hall State (per page 36)
4. Bit 6 (10000
1
100000): Motor Over Temp (per page 36)
5. Bit 11 (
1
00001100000): Primary Encoder Fault (per page 36)
SynqNet® Setup