Unit Preparation
EOF 20/20
31
8. Press the Heat Switch to the OFF
position
9. The wet element should quickly dry within 15 seconds.
Proceed to Section 4-4.
If the Heating Element does not dry within 15-30 sec-
onds, refer to the Troubleshooting procedure in Section
7-1.
10
10
EOF-20
4-03. Heating Element test (Continued from previous page)
4-04. Filter Pump Test
1.
Follow steps shown in Section 4-1.
2. Open Cabinet Door.
3. Place the palm of your hand over the Quick
Disconnect
for the Filter Pan Hose.
4. Briefly press the Pump Switch to the PUMP
position then press the Pump Switch to the OFF
position. If suction is felt on the palm, the
pump is operating correctly. Proceed to Section
4.5.
If no suction is felt, refer to the Troubleshooting
procedure in Section 7-2.
3
2
1
1
2
3
The following test will ensure the Filter Pump is operating correctly.
Summary of Contents for EOF-20/20
Page 2: ......
Page 4: ......
Page 7: ...v Table Of Contents EOF 20 20 ...
Page 8: ...vi Table Of Contents EOF 20 20 Notes ...
Page 16: ...4 Introduction EOF 20 20 Notes ...
Page 22: ...10 Overview EOF 20 20 3 01 EOF 20 Basket Elevator and Baskets 4 2 1 3 ...
Page 24: ...Overview EOF 20 20 12 3 02 EOF 20 Control Panel 6 5 4 3 2 1 7 ...
Page 26: ...14 Overview EOF 20 20 3 03 EOF 20 Left Lower Cabinet Area 2 1 3 ...
Page 28: ...16 Overview EOF 20 20 3 04 EOF 20 Right Lower Cabinet Area 2 1 3 ...
Page 30: ...18 Overview EOF 20 20 3 05 EOF 20 Basket Hanger and Baskets 2 1 3 ...
Page 32: ...20 Overview EOF 20 20 3 06 Filter Pan Assembly 6 4 7 3 2 1 5 ...
Page 64: ...52 Fryer Operation EOF 20 20 Notes ...
Page 70: ...58 Cleaning EOF 20 20 Notes ...
Page 90: ...78 Parts List EOF 20 20 Notes ...
Page 100: ...88 Wiring Diagram EOF 20 20 Notes ...
Page 101: ......