73
12.1.2 VEHICLE CHARGE IN DLM MODE
This charging mode can be set using the “I-CON MANAGER” APP or on the graphic interface and completing the
configuration in order to:
1. Determine the type of energy meter installed upstream.
2. Set the limit power of your domestic system
As already indicated in the previous chapters, an energy meter (code GWD6812 or GWD6817) must be installed
upstream of the electrical system and it must be connected to the charging station via the RS485 line
The presence of the external energy meter connected to the charging station and the indication of the system
variables allow the station to manage charging in a completely autonomous manner, varying the power based on
the trend of the domestic electrical consumption, thereby optimising charging as much as possible.
NOTE= for 4.6 and 7.4kW single-phase stations, it is only possible to associate the single-phase energy meter
GWD6812 to ensure that the setting related to system power is congruous. The same also applies for 11kW three-
phase versions, where it will only be possible to associate the three-phase energy meter GWD6817.
To enable a recharging session:
1 Make sure there are no errors on the charging station
Fixed green
2
Insert the charging plug in the socket-outlet of the station, and in the vehicle
or
Connect the mobile connector to the vehicle.
Fixed green
3
The station will decide if it is possible to start the charge or if it must
be kept in stand-by based on the domestic consumption detected.
The user does not have to do anything
Flashing blue
(charging in stand-by)
or
Fixed blue
(charging started)
4
At every moment, the station decides if it is possible to continue with
charging, or if it must be suspended to permit domestic consumption.
There is no action or operation that the customer can perform
5
Charging session in progress but car battery charged
or
Session suspended due to an increase in domestic consumption
Flashing blue
6
The charging session was ended by the customer by disconnecting
the cable from the vehicle
Flashing green
7
If the station detects no errors, it will return to standby
Fixed green
12.2 RFID OPERATING MODE
The station activates the charging session once a valid RFID card has been swiped.
There are two ways of adding more RFID cards to the local list:
METHOD 1
# Action to be carried out
RGB LED / Touch Slider status
1 Swipe the MASTER key across the RFID reader to access the secret menu From fixed green to flashing white
2 Move in the menu using the slider
until
reaching the item RFID CARD MEMORISATION
Flashing white
3 Confirm the selection with the push-button
Flashing white/ clockwise light
effects
4
Take each card that you want to add to the list and swipe them across
the RFID scanner. The colour of the RGB LED and the text on the main
display indicate correct acquisition
Fixed green for 2 seconds
5 To exit the RFID card memorisation menu and return to the previous
item, wait until timeout ends.
6 Go to the EXIT item in the menu
From flashing white to fixed green
Summary of Contents for JOINON I-CON PREMIUM GWJ3201A
Page 15: ...15 Fissaggio mediante staffe supporto palo GW46551 ...
Page 41: ......
Page 55: ...55 Fixing with the aid of support brackets on pole GW46551 ...
Page 81: ......
Page 95: ...95 Fixation sur pattes support du poteau GW46551 ...
Page 121: ......
Page 135: ...135 Fijación mediante grapas de soporte poste GW46551 ...
Page 161: ......
Page 175: ...175 Befestigung mit Masthalterungen GW46551 ...
Page 201: ......
Page 215: ...215 Fixarea cu ajutorul suporturilor de susținere a stâlpului GW46551 ...
Page 241: ......
Page 255: ...255 Rögzítés oszlopra való tartókengyelekkel GW46551 ...
Page 281: ......
Page 295: ...295 Bevestiging met behulp van steunbeugels paal GW46551 ...
Page 321: ......
Page 322: ......
Page 323: ......