53
6.6. DLM AUTOSTART VERSION – REQUIREMENTS FOR THE USE OF THE DYNAMIC
MANAGEMENT FUNCTIONALITY OF THE CHARGING POWER
The charging station can be set to dynamically manage the charging power to the electric vehicle. To be able to
implement this logic, the electrical system must be prepared accordingly. An energy meter (code GWD6812 or
GWD6817) must be installed upstream of the electrical system that is able to measure all domestic consumptions.
This energy meter must then be connected to the charging station via an RS485 line in order to permit communi-
cation on the Modbus protocol. Refer to section 12.1.2 for more details.
DEVICE INSTALLATION AND CONNECTION
7.
Before proceeding with device installation, remove the packaging, paying particular attention to not damage the
casing.
Make sure there is no condensation inside the packaging. Otherwise, install the device only when it is completely
dry.
All the installation operations must be carried out in compliance with the directive in force.
All operations that involve moving large weights must be done by two people.
Connection must be carried out when the system is de-energised and by qualified personnel.
Scrupulously check that the device is not energised when accessing it inside.
After completing the installation of the wallbox, remove the protective film from the
front display..
7.1.
GENERAL INSTALLATION REQUIREMENTS
• The device must be installed in a suitable environment that satisfies the information described in chapter
“6.
Preparation for device installation”
. Furthermore, the elements used in the rest of the installation must be com-
patible with the device and compliant with the applicable law.
• The ventilation and work space must be suitable for the maintenance operations according to the directive in
force.
• The external connection devices must be suitable and observe the distance established by the directive in force.
• The section of the connection cables must be suitable for the maximum current intensity.
• The system must have everything necessary to guarantee the proper operation of the charging station based
on the preferred charging mode that was selected, in particular for the version
AUTOSTART DLM.
If this is not
guaranteed, station operation will be limited or will not function.
Summary of Contents for JOINON I-CON PREMIUM GWJ3201A
Page 15: ...15 Fissaggio mediante staffe supporto palo GW46551 ...
Page 41: ......
Page 55: ...55 Fixing with the aid of support brackets on pole GW46551 ...
Page 81: ......
Page 95: ...95 Fixation sur pattes support du poteau GW46551 ...
Page 121: ......
Page 135: ...135 Fijación mediante grapas de soporte poste GW46551 ...
Page 161: ......
Page 175: ...175 Befestigung mit Masthalterungen GW46551 ...
Page 201: ......
Page 215: ...215 Fixarea cu ajutorul suporturilor de susținere a stâlpului GW46551 ...
Page 241: ......
Page 255: ...255 Rögzítés oszlopra való tartókengyelekkel GW46551 ...
Page 281: ......
Page 295: ...295 Bevestiging met behulp van steunbeugels paal GW46551 ...
Page 321: ......
Page 322: ......
Page 323: ......