background image

URBAN WB DC Series

INSTALLATION GUIDE

(M328A01-03-22A)

Summary of Contents for URBAN WB DC Series

Page 1: ...URBAN WB DC Series INSTALLATION GUIDE M328A01 03 22A...

Page 2: ...URBAN WB DC 2 Installation Guide...

Page 3: ...3 4 5 B 5 D 5 F 5 G 6 7 02 22 M328A01 03 22A Changes in the following sections 1 3 5 I 6 7 Disclaimer CIRCUTOR SA reserves the right to make modifications to the device or the unit specifications set...

Page 4: ...means without the prior written permission of the original manufacturer Information provided in this manual is intended to be accurate and reliable However the original manufacturer assumes no respon...

Page 5: ...ctrical Safety Instructions 10 D EVSE Classification 11 3 Oveview 12 4 Dimensions 14 5 Installation 16 A Space requirements 17 B Plates fixation 18 C Positioning 19 D Opening 20 E Device fixation 21 F...

Page 6: ...URBAN WB DC 6 Installation Guide 1...

Page 7: ...en So hello THE FOLLOWING SYMBOLS ARE USED FOR IMPORTANT SAFETY INFORMATION IN THIS DOCUMENT Compliant with IEC 61851 Electric vehicle conductive charging system IEC 61851 1 and IEC 61851 23 Compliant...

Page 8: ...is device If modified CIRCUTOR will reject all responsibility and the warranty will be void Comply strictly with electrical safety regulations according to your country Do not make repairs or manipula...

Page 9: ...current device RCD upstream of the Charge Point These electrical protections and the rest of the installation have to be aligned with the local and national rules The selectivity of the protections h...

Page 10: ...s necessary to handle equipment that is plugged in be sure hands are dry and when possible wear nonconductive gloves protective clothes and shoes with insulated soles Never handle electrical equipment...

Page 11: ...o AC supply network Permanently connected 2 Power supply Output DC EV supply equipment 3 Environmental conditions Indoor 4 Access Equipment for locations with restricted access and Equipment for locat...

Page 12: ...URBAN WB DC 12 Installation Guide 3 What s included 2x Charge Point Installation User Manual Wall plates URBAN WB DC key security key Fixation screw 2x Cable roller 1x Installation guide...

Page 13: ...Guide Overview 2 2 5 5 4 10 1 1 Hat 2 Key lock access 3 Ventilation 4 Cable output 5 Wall support 6 Base 7 LED Beacon light 8 START button 9 STOP button 10 Power input 7 8 9 3 6 1 2 3 5 7 4 5 2 10 6...

Page 14: ...URBAN WB DC 14 Installation Guide 219 382 628 17 984 4 Measures in mm Charge Point...

Page 15: ...URBAN WB DC 15 Installation Guide Dimensions Wall plates 82 17 240...

Page 16: ...commended that the installation kit would be installed in brick or concrete wall Before the installation a qualified installer must check that the wall is in a perfect condition and which screws and a...

Page 17: ...device some space shall be reserved for usability maintenance and safety reasons Please comply accordingly to your country specifications The next picture shows the minimum distances 1 y distance sha...

Page 18: ...Guide B Plates fixation Install the plates on the wall considering the distances and the wall holes template shown on the image below Measures in mm Front view y 2 628 2 y distance shall be chosen acc...

Page 19: ...URBAN WB DC 19 Installation Guide C Positioning Place the Charge Point on the previously installed wall plates...

Page 20: ...ward the Tamper switch 3 to operate the Charge Point D Opening 3 Tamper Switch The Charge Point has a security switch antitamper protection installed that will avoid any charging session if the doors...

Page 21: ...Guide E Device fixation Once the charging point is opened tighten the provided fixation screw in the lower wall plate in order to secure the device to the wall and make sure all components remain as b...

Page 22: ...ucing cables through the rounded lower part as indicated in the pictures below Lower Upper Cable entry Cable entry It is highly recommended to install around an extra 20 cm of power supply cables and...

Page 23: ...NT Connect to the 400V Do not forget to connect the ground cable to the ground terminal Terminal block maximum cross section 16mm2 Type of cable allowed by the terminal block Aluminium copper Make sur...

Page 24: ...d that all cables should remain inside 4 CHECK THE PLUGS Plugs should be in good conditions before starting the device 5 ELECTRICAL PROTECTIONS If the device includes electrical protections rearm all...

Page 25: ...URBAN WB DC Basic Serie it is not configurable In order to see how to use it see chapter 6 How to use URBAN WB DC Basic in this manual In order to use and configure the Charging Station there is an U...

Page 26: ...r C Charging The charge transaction starts when STOP button gets red The LED beacon still continues being blue As detailed in previous chapters the device has a LED beacon light and two illuminated bu...

Page 27: ...ted from the EV the LED beacon turns back to green A status according to IEC 61851 Until the status of STOP button does not change from red to off the charging station is not available to start a new...

Page 28: ...inal output power Frecuency 50 60 Hz Charging protocols CCS2 OPTIONAL DEVICES Electrical Protections RCD type B 30 mA MCB curve C MODELS SPECIFICATIONS Models URBAN WB DC SATELLITE URBAN WB DC BASIC M...

Page 29: ...ure rating IP54 IK10 Enclosure door lock Security Key lock Enclosure material Aluminium ABS Enclosure access Frontal door Environment Indoor Cable support Cable roller Cable length 5 5 meters Weight U...

Page 30: ...URBAN WB DC 30 Installation Guide...

Page 31: ...evices has been improperly used or the storage installation and maintenance instructions listed in this manual have not been followed Improper usage is defined as any operating or storage condition co...

Page 32: ...CIRCUTOR SA Vial Sant Jordi s n 08232 Viladecavalls Barcelona Tel 34 93 745 29 00 Fax 34 93 745 29 14 www circutor com central circutor com...

Reviews: