BCT_T Rev.00 05-2015
pag. 131
The following table illustrates the meaning of the indication codes.
Code
Meaning
dEF
Defrosting will be in progress.
Loc
The keyboard is locked, see paragraph 5.10 "Lock/unlock the keyboard".
UnL
The keyboard has been locked, see paragraph 5.10 "Lock/unlock the keyboard".
8.4.1
– ALARMS
The following table illustrates the meaning of the alarm codes.
Code
Meaning
tiM
Temperature-controlled blast chilling or deep freezing not concluded within maximum duration alarm
(HACCP alarm).
Solutions:
-
check the value of parameters r5 and r6 and AA.
Main consequences:
-
the device will memorise the alarm
-
the alarm output will be activated.
AL
Minimum temperature alarm.
Solutions:
-
check the temperature of the cabinet
-
check the value of parameters A1 and A2.
Main consequences:
-
the alarm output will be activated.
AH
Maximum temperature alarm (HACCP alarm).
Solutions:
-
check the temperature of the cabinet
-
check the value of parameters A4 and A5.
Main consequences:
-
the device will memorise the alarm
-
the alarm output will be activated.
id
Door open alarm
Solutions:
-
check the door conditions
-
check the value of parameters i0 and i1.
Main consequences:
-
the effect established with parameter i0
-
the alarm output will be activated.