32
Starting System
6.12
Starting System
6.12.1 Starter condition check
Preconditions
Engine is stopped and starting disabled.
Starter condition check
1. Check starter securing screws for secure seating.
2. Tighten loose screw connections.
3. Check wiring ( Page 6 55).
6.12.2 Air starter manual operation
DANGER
Unguarded rotating and moving engine components.
Risk of serious injury
danger to life!
Before barring or starting the engine, ensure that nobody is in the danger zone.
WARNING
Engine noise above 85 dB (A).
Risk of damage to hearing!
Wear ear protectors.
Air starter manual operation
1. Press pushbutton for manual start and hold it.
2. Allow compressed air to enter the air starter until
the engine fires evenly.
3. Release pushbutton.