Troubleshooting
15
Fault code
Alarm text
Meaning
Task
354
OPEN_LOAD
CYL. B4
Disconnection in wiring to
solenoid valve cylinder B4;
Misfiring
1. Check wiring.
2. Contact Service.
355
OPEN_LOAD
CYL. B5
Disconnection in wiring to
solenoid valve cylinder B5;
Misfiring
1. Check wiring.
2. Contact Service.
356
OPEN_LOAD
CYL. B6
Disconnection in wiring to
solenoid valve cylinder B6;
Misfiring
1. Check wiring.
2. Contact Service.
357
OPEN_LOAD
CYL. B7
Disconnection in wiring to
solenoid valve cylinder B7;
Misfiring
1. Check wiring.
2. Contact Service.
358
OPEN_LOAD
CYL. B8
Disconnection in wiring to
solenoid valve cylinder B8;
Misfiring
1. Check wiring.
2. Contact Service.
359
OPEN_LOAD
CYL. B9
Disconnection in wiring to
solenoid valve cylinder B9;
Misfiring
1. Check wiring.
2. Contact Service.
360
OPEN_LOAD
CYL. B10
Disconnection in wiring to
solenoid valve cylinder B10;
Misfiring
1. Check wiring.
2. Contact Service.
361
POWER STAGE
FAIL 1
Defect in ECU (solenoid valve
power stage)
Contact Service.
362
POWER STAGE
FAIL 2
Defect in ECU (solenoid valve
power stage)
Contact Service.
363
STOP POWER
STAGE 1
Solenoid valve or wiring or
ECU defective
automatic engine shutdown
1. Check wiring.
2. Try to re-start the engine
( Page 3 2).
3. Contact Service.
364
STOP POWER
STAGE 2
Solenoid valve or wiring or
ECU defective
automatic engine shutdown
1. Check wiring.
2. Try to re-start the engine
( Page 3 2).
3. Contact Service.
365
STOP
MV-WIRING
Solenoid-valve wiring faulty;
automatic engine shutdown
1. Check wiring.
2. Try to re-start the engine
( Page 3 2).
3. Contact Service.
381
TRAN.OUT1
PLANT DEF
Binary transistor output plant 1
defective
Contact Service.
382
TRAN.OUT2
PLANT DEF
Binary transistor output plant 2
defective
Contact Service.
383
TRAN.OUT3
PLANT DEF
Binary transistor output plant 3
defective
Contact Service.
384
TRAN.OUT4
PLANT DEF
Binary transistor output plant 4
defective
Contact Service.
M015403/00E 02-09
© MTU
www.generent.ru
Summary of Contents for 12V 4000 G 41
Page 22: ...II Table of Contents M015403 00E 02 09 MTU w w w g e n e r e n t r u...
Page 30: ...II Table of Contents M015403 00E 02 09 MTU w w w g e n e r e n t r u...
Page 38: ...8 Maintenance Schedule Application Group 3A M015403 00E 02 09 MTU w w w g e n e r e n t r u...
Page 40: ...II Table of Contents M015403 00E 02 09 MTU w w w g e n e r e n t r u...
Page 116: ...58 Engine Governor Electronic Control System M015403 00E 02 09 MTU w w w g e n e r e n t r u...
Page 118: ...II Table of Contents M015403 00E 02 09 MTU w w w g e n e r e n t r u...
Page 124: ...w w w g e n e r e n t r u...