![Geko 12V 4000 G 41 Operating Instructions Manual Download Page 66](http://html1.mh-extra.com/html/geko/12v-4000-g-41/12v-4000-g-41_operating-instructions-manual_2206052066.webp)
8
Valve Gear
6.4
Valve Gear
6.4.1
Valve gear lubrication
Preconditions
Engine is stopped and starting disabled.
Material
Designation / Use
Part No.
Qty.
Engine oil
FLS
Valve gear lubrication
1. Remove cylinder-head covers ( Page 6 12).
2. Fill oil chambers of valve bridges with oil.
3. Fill oil chambers of rocker arms and adjusting
screws with oil.
4. Install cylinder-head covers ( Page 6 12).
6.4.2
Valve clearance check and adjustment
Preconditions
Engine is stopped and starting disabled.
Engine coolant temperature is max. 40 C.
Valves are closed.
Special tools
Designation / Use
Part No.
Qty.
Feeler gauge
TC
Torque wrench
TC
Allen key
TC
Open end spanner
TC
Preparatory steps
1. Remove cylinder-head cover ( Page 6 12).
2. Install barring tool ( Page 6 1).
M015403/00E 02-09
© MTU
www.generent.ru
Summary of Contents for 12V 4000 G 41
Page 22: ...II Table of Contents M015403 00E 02 09 MTU w w w g e n e r e n t r u...
Page 30: ...II Table of Contents M015403 00E 02 09 MTU w w w g e n e r e n t r u...
Page 38: ...8 Maintenance Schedule Application Group 3A M015403 00E 02 09 MTU w w w g e n e r e n t r u...
Page 40: ...II Table of Contents M015403 00E 02 09 MTU w w w g e n e r e n t r u...
Page 116: ...58 Engine Governor Electronic Control System M015403 00E 02 09 MTU w w w g e n e r e n t r u...
Page 118: ...II Table of Contents M015403 00E 02 09 MTU w w w g e n e r e n t r u...
Page 124: ...w w w g e n e r e n t r u...