![Geko 12V 4000 G 41 Operating Instructions Manual Download Page 115](http://html1.mh-extra.com/html/geko/12v-4000-g-41/12v-4000-g-41_operating-instructions-manual_2206052115.webp)
Engine Governor (Electronic) / Control System
6 57
6.20.2 ECU checking plug-in connections
Preconditions
Engine is stopped and starting disabled.
Special tools
Designation / Use
Part No.
Qty.
Connector pliers
TC
ECU checking plug-in connections
1. Use connector pliers (3) to make certain that all
plug-in connections of ECU are securely seated.
2. Tighten loose bayonet union nuts (2) with
connector pliers (3) by turning them clockwise
until they lock into place.
3. Ensure that unassigned connector sockets are
protected with covering caps.