A-2
L60 Line Phase Comparison System
GE Multilin
A.1 PARAMETER LIST
APPENDIX A
A
6244
SRC 2 Igd Angle
Amps
Source 2 differential ground current angle
6272
SRC 3 Ia RMS
Amps
Source 3 phase A current RMS
6274
SRC 3 Ib RMS
Amps
Source 3 phase B current RMS
6276
SRC 3 Ic RMS
Amps
Source 3 phase C current RMS
6278
SRC 3 In RMS
Amps
Source 3 neutral current RMS
6280
SRC 3 Ia Mag
Amps
Source 3 phase A current magnitude
6282
SRC 3 Ia Angle
Degrees
Source 3 phase A current angle
6283
SRC 3 Ib Mag
Amps
Source 3 phase B current magnitude
6285
SRC 3 Ib Angle
Degrees
Source 3 phase B current angle
6286
SRC 3 Ic Mag
Amps
Source 3 phase C current magnitude
6288
SRC 3 Ic Angle
Degrees
Source 3 phase C current angle
6289
SRC 3 In Mag
Amps
Source 3 neutral current magnitude
6291
SRC 3 In Angle
Degrees
Source 3 neutral current angle
6292
SRC 3 Ig RMS
Amps
Source 3 ground current RMS
6294
SRC 3 Ig Mag
Degrees
Source 3 ground current magnitude
6296
SRC 3 Ig Angle
Amps
Source 3 ground current angle
6297
SRC 3 I_0 Mag
Degrees
Source 3 zero-sequence current magnitude
6299
SRC 3 I_0 Angle
Amps
Source 3 zero-sequence current angle
6300
SRC 3 I_1 Mag
Degrees
Source 3 positive-sequence current magnitude
6302
SRC 3 I_1 Angle
Amps
Source 3 positive-sequence current angle
6303
SRC 3 I_2 Mag
Degrees
Source 3 negative-sequence current magnitude
6305
SRC 3 I_2 Angle
Amps
Source 3 negative-sequence current angle
6306
SRC 3 Igd Mag
Degrees
Source 3 differential ground current magnitude
6308
SRC 3 Igd Angle
Amps
Source 3 differential ground current angle
6336
SRC 4 Ia RMS
Amps
Source 4 phase A current RMS
6338
SRC 4 Ib RMS
Amps
Source 4 phase B current RMS
6340
SRC 4 Ic RMS
Amps
Source 4 phase C current RMS
6342
SRC 4 In RMS
Amps
Source 4 neutral current RMS
6344
SRC 4 Ia Mag
Amps
Source 4 phase A current magnitude
6346
SRC 4 Ia Angle
Degrees
Source 4 phase A current angle
6347
SRC 4 Ib Mag
Amps
Source 4 phase B current magnitude
6349
SRC 4 Ib Angle
Degrees
Source 4 phase B current angle
6350
SRC 4 Ic Mag
Amps
Source 4 phase C current magnitude
6352
SRC 4 Ic Angle
Degrees
Source 4 phase C current angle
6353
SRC 4 In Mag
Amps
Source 4 neutral current magnitude
6355
SRC 4 In Angle
Degrees
Source 4 neutral current angle
6356
SRC 4 Ig RMS
Amps
Source 4 ground current RMS
6358
SRC 4 Ig Mag
Degrees
Source 4 ground current magnitude
6360
SRC 4 Ig Angle
Amps
Source 4 ground current angle
6361
SRC 4 I_0 Mag
Degrees
Source 4 zero-sequence current magnitude
6363
SRC 4 I_0 Angle
Amps
Source 4 zero-sequence current angle
6364
SRC 4 I_1 Mag
Degrees
Source 4 positive-sequence current magnitude
6366
SRC 4 I_1 Angle
Amps
Source 4 positive-sequence current angle
6367
SRC 4 I_2 Mag
Degrees
Source 4 negative-sequence current magnitude
6369
SRC 4 I_2 Angle
Amps
Source 4 negative-sequence current angle
6370
SRC 4 Igd Mag
Degrees
Source 4 differential ground current magnitude
6656
SRC 1 Vag RMS
Volts
Source 1 phase AG voltage RMS
Table A–1: FLEXANALOG DATA ITEMS (Sheet 2 of 9)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
Summary of Contents for UR series
Page 2: ......
Page 4: ......
Page 12: ...xii L60 Line Phase Comparison System GE Multilin TABLE OF CONTENTS ...
Page 32: ...1 20 L60 Line Phase Comparison System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 54: ...2 22 L60 Line Phase Comparison System GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Page 438: ...7 8 L60 Line Phase Comparison System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Page 478: ...8 40 L60 Line Phase Comparison System GE Multilin 8 3 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Page 502: ...A 10 L60 Line Phase Comparison System GE Multilin A 1 PARAMETER LIST APPENDIXA A ...
Page 584: ...B 82 L60 Line Phase Comparison System GE Multilin B 4 MEMORY MAPPING APPENDIXB B ...
Page 622: ...D 10 L60 Line Phase Comparison System GE Multilin D 1 PROTOCOL APPENDIXD D ...
Page 634: ...E 12 L60 Line Phase Comparison System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...
Page 642: ...F 8 L60 Line Phase Comparison System GE Multilin F 3 WARRANTY APPENDIXF F ...