background image

Single-Phase Solid State Relay

HSR-2

Thank you for purchasing Hanyoung Nux products. Please read the instruction 

manual carefully before using this product, and use the product correctly. 

Also, please keep this instruction manual where you can view it any time. 

INSTRUCTION MANUAL

Safety information

Please read the safety information carefully before the use, and use the product correctly.

The alerts declared in the manual are classified into 

Danger 

and 

Warning 

according to their importance.

Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury
Indicates a potentially hazardous situation which, if not avoided, may result in minor injury or 

properties damage

DANGER
WARNING

CAUTION

• Please read the safety information carefully before the use, 

   and use the product correctly.

•  If there is a possibility that a malfunction or abnormality  of 

   this product may lead to a serious accident, install an 

   appropriate protection circuit on the outside and plan to  

   prevent accidents. 

• Please supply the rated power voltage, in order to prevent 

   product breakdowns or malfunctions. 

• To prevent electric shocks and malfunctions, do not supply 

   power until the wiring is completed.

• Please disassemble the product after turning OFF the power. 

• Any use of the product other than those specified by the 

  manufacturer may result in personal injury or property damage.

• Please use this product after installing it to a panel, 

  because there is a risk of electric shock. 

•  4 - 32 V d.c model signal inputs must be supplied with

  an isolated and limited voltage/current or Class2,

  SELV power supply.

• Short circuit rated current is 3kA.

• Please make sure that the product specifications are the same as you ordered. 

• Please use the product in places where corrosive gases 

   (especially harmful gases, ammonia, etc.) and flammable 

   gases are not  generated.

• Please use the product in places without liquids, oils, 

   chemicals, steam, dust, salt, iron, etc. (pollution degree 1 or 2).

• Please avoid places where large inductive interference, static 

  electricity,magnetic noise are generated.

• Please avoid places with heat accumulation caused by direct 

   sunlight, radiant heat, etc.

• When water enters, short circuit or fire may occur, so please 

   inspect the product carefully.

• Do not connect anything to the unused terminals.

• For DC types, please wire correctly, 

  after checking the polarity of the terminals.  

• When disposing of the product, treat it as industrial waste.

• Since a heat sink corner is sharp, it would lead to a serious injury.

•  When electricity flows, desktop or heat sink's corner temperature 

would be high so that it could lead people to suffer burns.

• When it is out of order, please separate HSR from head sink and

  change only HSR.

• This model has epoxy molding for the purpose of safety, 

   reliability and extends of the life.

•  When applying an electric current, HSR is heated more and more. 

  So, it has more durable at low heat sink temperature and 

  ambient temperature. 

•   Note 1) The N option model must be installed and used with a 

heatsink (HSN or HSM series, sold separately) of our company's 

appropriate specifications. 

However). When using a separate heat sink, it is recommended to 

select and install the heat sink size based on the thermal 

resistance value (Note 1).

• The input/output terminals are subject to electric shock risk.

   Never let the input/output  terminals come in contact 

   with your body  or conductive substances.

DANGER

CAUTION

WARNING

MC0801KE231018

▍Suffix code

Model

Low

HSR-2D10LZ□ HSR-2D20LZ□ HSR-2D30LZ□ HSR-2D40LZ□ HSR-2D50LZ□ HSR-2D70LZ□

HSR-2D10LR□ HSR-2D20LR□ HSR-2D30LR□ HSR-2D40LR□ HSR-2D50LR□ HSR-2D70LR□

High

HSR-2D10HZ□ HSR-2D20HZ□ HSR-2D30HZ□ HSR-2D40HZ□ HSR-2D50HZ□ HSR-2D70HZ□

HSR-2D10HR□ HSR-2D20HR□ HSR-2D30HR□ HSR-2D40HR□ HSR-2D50HR□ HSR-2D70HR□

L

O

A

D

Rated Load

Voltage

Low

24 - 240 V a.c. 50/60 Hz

High

24 - 480 V a.c. 50/60 Hz

Peak Voltage

(Non-repetition)

Low

1,200V

High

Rated load current

10A

20A

30A

40A

50A

70A

Surge current 60Hz

(8.3ms No repetition)

Low

170A

260A

420A

525A

High

170A

250A

370A

525A

Surge current 50Hz

(10ms No repetition)

Low

160A

250A

400A

500A

High

160A

240A

340A

500A

Leakage current

Less than 20 mA

Output ON voltage dropping

Less than 1.6 V (R.M.S)

I

N

P

U

T

Rated Voltage

5 - 24 V d.c.

Operating Voltage Range 

(ON Voltage)

4 - 32 V d.c.

return voltage (OFF Voltage)

Less than 3 V

Impedance

Less than 4 kΩ

Current Consumption

Constant current method: 14 mA or less

Response Time

1/2 Cycle + 1 ms max. (“R”type below 1ms)

Insulating Resistance

500 V d.c., 100 MΩ (Between input and output and case)

Dielectric strength

2,500 V a.c. (For 1min at 60㎐)

Rated impulse withstand voltage 

(Uimp)

2,500 V

Vibration resistance

10 - 55 Hz, Double amplitude : 1.5 mm, X-Y-Z each axis direction for 2 hour

Shock resistance

1,000 ㎨, X·Y·Z each axis 3 time

Storage Temperature

-30 ~ 90 ℃

Ambient Temperature & Humidity

-30 ~ 80 ℃ (No Condensation), 45 ~ 85 % RH

Pollution level grade

2level pollution

bolt tightening torque

Input terminal: 0.05 Nm / Output terminal: 0.25 Nm

Usage

Resistive load

Accepted standard

 (EN 60947-4-3)    

    

Weight

Approx 110 g

Approx 120 g

█ 

DC input

Model

Low

HSR-2A10LZ□ HSR-2A20LZ□

HSR-2A30LZ□

HSR-2A40LZ□

HSR-2A50LZ□

HSR-2A70LZ□

HSR-2A10LR□ HSR-2A20LR□

HSR-2A30LR□

HSR-2A40LR□

HSR-2A50LR□

HSR-2A70LR□

High

HSR-2A10HZ□ HSR-2A20HZ□ HSR-2A30HZ□ HSR-2A40HZ□ HSR-2A50HZ□ HSR-2A70HZ□
HSR-2A10HR□ HSR-2A20HR□ HSR-2A30HR□ HSR-2A40HR□ HSR-2A50HR□ HSR-2A70HR□

L

O

A

D

Rated Load

Voltage

Low

24 - 240 V a.c. 50/60Hz

High

24 - 480 V a.c. 50/60Hz

Peak Voltage

(Non-repetition)

Low

1,200V

High

Rated load current

10A

20A

30A

40A

50A

70A

Surge current 60Hz

(8.3ms No repetition)

Low

170A

260A

420A

525A

High

170A

250A

370A

525A

Surge current 50Hz

(10ms No repetition)

Low

160A

250A

400A

500A

High

160A

240A

340A

500A

Leakage current

Less than 20 mA

Output ON voltage dropping

Less than 1.6 V (R.M.S)

I

N

P

U

T

Rated Voltage

100-240 V a.c.  50/60Hz (public)

Operating Voltage Range 

(ON Voltage)

90-264 V a.c.  50/60Hz (public)

return voltage (OFF Voltage)

Less than 50 V

Impedance

Less than 40 kΩ

Current Consumption

Less than 14 mA

Response Time

1/2 Cycle + 1 ms max. (“R”type below 1ms)

Insulating Resistance

500 V d.c., 100 MΩ (Between input and output and case)

Dielectric strength

2,500 V a.c. (For 1min at 60㎐)

Rated impulse withstand voltage 

(Uimp)

2,500 V

Vibration resistance

10 - 55 Hz, Double amplitude : 1.5 mm, X-Y-Z each axis direction for 2 hour

Shock resistance

1,000 ㎨, X·Y·Z each axis 3 time

Storage Temperature

-30 ~ 90 ℃

Ambient Temperature & Humidity

-30 ~ 80 ℃ (No Condensation), 45 ~ 85 % RH

Pollution level grade

2 level pollution

bolt tightening torque

Input terminal: 0.05 Nm / Output terminal: 0.25 Nm

Usage

Resistive load

Accepted standard

 (EN 60947-4-3)    

   

Weight

Approx 110 g

Approx 120 g

█ 

AC input

▍Dimensions

[ Unit  : ㎜ ]

▍Equivalent Circuit

※ 

This model does not have a fuse internally.  So we suggest using 

     fast-acting fuse separately on the outside as following picture.

     (using gG/gL type fuse according to IEC 60269 standard)

5-24Vd.c.

100-240Va.c.

Load voltage

Load

Load voltage

Load

Voltage output of

temperature controller, PLC etc.

▍Connection

5-24Vd.c.

100-240Va.c.

Load voltage

Load

Load voltage

Load

Voltage output of

temperature controller, PLC etc.

• Please make intervals more than the sizes in the following picture. 

• Please install wiring duct less than half the height of the heat sink

  to prevent the flow of air. 

• It is good to use Hanyoung Nux's HSR in lower than ambient

  temperature 40 ℃ so,  please use it lower than standard temperature.

• When installing the HSR, be sure to installthe heat sink in the 

  vertical direction.

• Unavoidably, if installed horizontally, theperformance of the

  product will drop below 50 %

▍Installation

• Using standard heat sink is mandatory for this product.

• Even the standard heat sink is used, HSR damage may occur if the environment temperature  

   rises or if the ventilation does not work well. (Environment temperature : over 40 ℃)

• The normal HSR element is damaged at the maximum temperature of 125 ℃ . When the  

   temperature of heat sink is 85° C, the temperature of the element reaches around 125 ℃ . 

   Therefore, during operation, measure the temperature of heat sink.

• When you connect HSR onto the heat sink, heat-transmitting grease is needed for smooth heat transmission.

• To prevent separation by vibration, tighten up with bolts.

• Do not use any insulating materials such as wood, plastic or rubber. 

  The standard heat sink  must be greased on the bottom side as shown and connected.

※ The heatproof silicon grease must be applied thoroughly on the heat sink as well as the bottom of HSR.

      The case side of heat sink needs to be installed on up and down directions.

▍Precautions during the use of Heat Sink

█ HSR-2D 

█ HSR-2A 

28, Gilpa-ro 71beon-gil,  Michuhol-gu, 

Incheon, Korea TEL : +82-32-876-4697 

http://www.hanyoungnux.com

HANYOUNGNUX CO.,LTD

64.0

42.0

4.4

48.0

R2.2

Ø4.4

27.3

4.0

42.16

64.35

Ă4.4

R2.2

48.0

4.4

31.8

4.0

64.0

42.0

4.4

48.0

R2.2

Ø4.4

27.3

4.0

42.16

64.35

Ă4.4

R2.2

48.0

4.4

31.8

4.0

64.0

42.0

4.4

48.0

R2.2

Ø4.4

27.3

4.0

42.16

64.35

Ă4.4

R2.2

48.0

4.4

31.8

4.0

█ HSM series

▍Heat Sink

60.0

L

4.

5

130.0

139.0

2-M4

5.

0

99.0

48.

5

99.0

5.0

█ HSN series

▍Input/Loder

Ambient Temperature(℃)

Lo

ad C

urr

ent (A)

Lo

ad C

urr

ent (A)

Lo

ad C

urr

ent (A)

Ambient Temperature(℃)

Ambient Temperature(℃)

HSR-2□55

10

10

15

20

25

30

35

40

20

30

40

50

60

70

80

90

0

HSR-2□20/25

HSR-2□10

10

10

15

20

25

30

35

40

20

30

40

50

60

70

80

90

0

HSR-2□40

HSR-2□30

10

10

20

30

40

50

55

60

70

20

30

40

50

60

70

80

90

0

HSR-2□70

HSR-2□50

Ambient Temperature(℃)

Lo

ad C

urr

ent (A)

Lo

ad C

urr

ent (A)

Lo

ad C

urr

ent (A)

Ambient Temperature(℃)

Ambient Temperature(℃)

HSR-2□55

10

10

15

20

25

30

35

40

20

30

40

50

60

70

80

90

0

HSR-2□20/25

HSR-2□10

10

10

15

20

25

30

35

40

20

30

40

50

60

70

80

90

0

HSR-2□40

HSR-2□30

10

10

20

30

40

50

55

60

70

20

30

40

50

60

70

80

90

0

HSR-2□70

HSR-2□50

Ambient Temperature(℃)

Lo

ad C

urr

ent (A)

Lo

ad C

urr

ent (A)

Lo

ad C

urr

ent (A)

Ambient Temperature(℃)

Ambient Temperature(℃)

HSR-2□55

10

10

15

20

25

30

35

40

20

30

40

50

60

70

80

90

0

HSR-2□20/25

HSR-2□10

10

10

15

20

25

30

35

40

20

30

40

50

60

70

80

90

0

HSR-2□40

HSR-2□30

10

10

20

30

40

50

55

60

70

20

30

40

50

60

70

80

90

0

HSR-2□70

HSR-2□50

▍Specifications

Model

Code

Information

HSR-2

□ □ □ □ □

Single-Phase Solid State Relay

Control 

Input Voltage D

4 - 32 V d.c.

A

90 - 240 V a.c.

Rated load current

10

10A

20

20A

30

30A

40

40A

50

50A

70

70A

Rated load voltage

L

24 - 240 V a.c. 

(Low voltage)

H

24 - 480 V a.c. 

(High voltage)

Operation method

(Switching Mode)

Z

Zero Cross Switching (Standard product)

R

Random Switching

Heatsink option

T Heat sink + bimetal mounting (50 A, 70 A only)

N No Heat sink  

※CAUTION 1) When using a separate heat sink, 

you must use a heat sink that meets the thermal resistance table.

Surge current Characteristics

10A ~ 40A

Input

current

(mA)

Input voltage(V)

Input voltage(V)

Input

current

(mA)

Load

current

(A)

Ambient temperature(℃)

HSR-2□40

HSR-2□30

HSR-2□10

80

70

60

HSR-2□70

HSR-2□50

Surge

current

(A)

Number of cycle(60Hz)

0

50

100

150

200

250

300

350

400

450

500

550

600

1

10

100

100C

HSR-2□70

HSR-2□50

Surge

current

(A)

Number of cycle(60Hz)

HSR-2□40

HSR-2□30

HSR-2□20/25

HSR-2□10

HSR-2□20

50A ~ 70A

Input

current

(mA)

Input voltage(V)

Input voltage(V)

Input

current

(mA)

Load

current

(A)

Ambient temperature(℃)

HSR-2□40

HSR-2□30

HSR-2□10

80

70

60

HSR-2□70

HSR-2□50

Surge

current

(A)

Number of cycle(60Hz)

0

50

100

150

200

250

300

350

400

450

500

550

600

1

10

100

100C

HSR-2□70

HSR-2□50

HSR-2□55

Surge

current

(A)

Number of cycle(60Hz)

HSR-2□40

HSR-2□30

HSR-2□20

HSR-2□10

HSR-2□20

ㆢ㈵Ÿㆤ

ㆤㆨ

ㇵㆥ

ㆢ㈵Ÿㆤ

ㆤㆨ

ㇵㆥ

※ CAUTION 1 (thermal resistance table)

• Input terminal wiring

• Output terminal wiring

1 X 0.5 mm² (1 X AWG20) or larger

1 X 1.5mm² (1 X AWG16) or larger

1 X 1.5 mm² (1 X AWG16) or less than 2 X 1.5 mm² (2 X AWG16) 1 X 16 mm² (1 X AWG6) or less than 2 X 6 mm² (2 X AWG10)

※ Connect the wiring suitable for the load current capacity

to the output terminal.

Model

Applicable Model

Capacity (A)

Length(L)

Weight

HSM-70

HSR-2□10□

10A

70 mm

352 (g)

HSM-110

HSR-2□20□

20A

110 mm

558 (g)

HSM-150

HSR-2□30□

HSR-2□40□

30A

40A

150 mm

758 (g)

HSN-80

HSR-2□50□

50A

80 mm

1,146 (g)

HSN-120

HSR-2□70□

70A

120 mm

1,712 (g)

load capacity

Heatsink thermal resistance (40℃ standard)

10A

2.00 ℃/W

20A

1.00 ℃/W

30A

0.50 ℃/W

40A

0.25 ℃/W

50A

0.30 ℃/W

70A

0.15 ℃/W

25 ℃ 10A 20A 30A 40A 50A 55A 70A

80 ℃ 6A

8A 15A 15A 15A 15A 16A

Reviews: