2.3.2 Order codes with process bus modules
Table 2-6: B30 order codes for horizontal units with process bus
74
Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, Laser
75
Channel 1 - G.703; Channel 2 - 1550 nm, single-mode Laser
76
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 1 Channel
77
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels
7A
820 nm, multimode, LED, 1 Channel
7B
1300 nm, multimode, LED, 1 Channel
7C
1300 nm, single-mode, ELED, 1 Channel
7D 1300 nm, single-mode, Laser, 1 Channel
7E
Channel 1 - G.703; Channel 2 - 820 nm, multimode
7F
Channel 1 - G.703; Channel 2 - 1300 nm, multimode
7G Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED
7H 820 nm, multimode, LED, 2 Channels
7I
1300 nm, multimode, LED, 2 Channels
7J
1300 nm, single-mode, ELED, 2 Channels
7K
1300 nm, single-mode, Laser, 2 Channels
7L
Channel 1 - RS422; Channel 2 - 820 nm, multimode, LED
7M Channel 1 - RS422; Channel 2 - 1300 nm, multimode, LED
7N Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, ELED
7P
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, Laser
7Q Channel 1 - G.703; Channel 2 - 1300 nm, single-mode Laser
7R
G.703, 1 Channel
7S
G.703, 2 Channels
7T
RS422, 1 Channel
7W RS422, 2 Channels
B30
- * **
- * * * - F **
- H **
- L **
- N **
- S **
- W/X **
Full Size Horizontal Mount
BASE UNIT
B30
|
|
| |
|
|
|
|
|
|
|
Base Unit
CPU
T |
| |
|
|
|
|
|
|
|
RS485 with 3 100Base-FX Ethernet, multimode, SFP with LC
U |
| |
|
|
|
|
|
|
|
RS485 with 1 100Base-TX Ethernet, SFP RJ-45 + 2 100Base-FX Ethernet, multimode,
SFP with LC
V |
| |
|
|
|
|
|
|
|
RS485 with 3 100Base-TX Ethernet, SFP with RJ-45
W |
| |
|
|
|
|
|
|
|
RS485 with 2 100Base-FX Ethernet, multimode ST + 10/100Base-TX Ethernet, RJ-45
SOFTWARE OPTIONS
00
| |
|
|
|
|
|
|
|
No software options
01
| |
|
|
|
|
|
|
|
Ethernet Global Data (EGD) protocol
03
| |
|
|
|
|
|
|
|
IEC 61850 protocol
04
| |
|
|
|
|
|
|
|
IEC 61850 and Ethernet Global Data (EGD) protocols
A0
| |
|
|
|
|
|
|
|
CyberSentry Lvl 1
A1
| |
|
|
|
|
|
|
|
CyberSentry Lvl 1 and Ethernet Global Data
A3
| |
|
|
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850
A4
| |
|
|
|
|
|
|
|
CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
B0
| |
|
|
|
|
|
|
|
IEEE 1588
B1
| |
|
|
|
|
|
|
|
IEEE 1588 and Ethernet Global Data
B3
| |
|
|
|
|
|
|
|
IEEE 1588 and IEC 61850
B4
| |
|
|
|
|
|
|
|
IEEE 1588, Ethernet Global Data, and IEC 61850
C0
| |
|
|
|
|
|
|
|
Parallel Redundancy Protocol (PRP)
C1
| |
|
|
|
|
|
|
|
PRP and Ethernet Global Data
C3
| |
|
|
|
|
|
|
|
PRP and IEC 61850
C4
| |
|
|
|
|
|
|
|
PRP, Ethernet Global Data, and IEC 61850
D0
| |
|
|
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1
D1
| |
|
|
|
|
|
|
|
IEEE 1588, CyberSentry Lvl 1, and Ethernet Global Data
D3
| |
|
|
|
|
|
|
|
IEEE 1588, CyberSentry Lvl 1, and IEC 61850
D4
| |
|
|
|
|
|
|
|
IEEE 1588, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
E0
| |
|
|
|
|
|
|
|
IEEE 1588 and PRP
E1
| |
|
|
|
|
|
|
|
IEEE 1588, PRP, and Ethernet Global Dada
E3
| |
|
|
|
|
|
|
|
IEEE 1588, PRP, and IEC 61850
E4
| |
|
|
|
|
|
|
|
IEEE 1588, PRP, Ethernet Global Data, and IEC 61850
F0
| |
|
|
|
|
|
|
|
PRP and CyberSentry Lvl1
F1
| |
|
|
|
|
|
|
|
PRP, CyberSentry Lvl1, and Ethernet Global Data
F3
| |
|
|
|
|
|
|
|
PRP, CyberSentry Lvl 1, and IEC 61850
F4
| |
|
|
|
|
|
|
|
PRP, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
G0
| |
|
|
|
|
|
|
|
IEEE 1588, PRP, and CyberSentry Lvl 1
G1
| |
|
|
|
|
|
|
|
IEEE 1588, PRP CyberSentry Lvl 1, Ethernet Global Data
G3
| |
|
|
|
|
|
|
|
IEEE 1588, PRP CyberSentry Lvl 1, and IEC 61850
G4
| |
|
|
|
|
|
|
|
IEEE 1588 PRP, CyberSentry Lvl 1, Ethernet Global Data, and IEC 61850
J0
| |
|
|
|
|
|
|
|
IEC 60870-5-103
J1
| |
|
|
|
|
|
|
|
IEC 60870-5-103 + EGD
J3
| |
|
|
|
|
|
|
|
IEC 60870-5-103 + IEC 61850
J4
| |
|
|
|
|
|
|
|
IEC 60870-5-103 + EGD + IEC 61850
K0
| |
|
|
|
|
|
|
|
IE PRP + IEC 60870-5-103
K1
| |
|
|
|
|
|
|
|
IE PRP + IEC 60870-5-103 + EGD
K3
| |
|
|
|
|
|
|
|
IE PRP + IEC 60870-5-103 + IEC 61850
K4
| |
|
|
|
|
|
|
|
IE PRP + IEC 60870-5-103 + EGD + IEC 61850
L0
| |
|
|
|
|
|
|
|
IEC 60870-5-103 + IE PRP + CyberSentry Lvl 1
L1
| |
|
|
|
|
|
|
|
IEC 60870-5-103 + IE PRP + CyberSentry Lvl 1 + EGD
L3
| |
|
|
|
|
|
|
|
IEC 60870-5-103 + IE PRP + CyberSentry Lvl 1 + IEC 61850
L4
| |
|
|
|
|
|
|
|
IEC 60870-5-103 + IE PRP + CyberSentry Lvl 1 + EGD + IEC 61850
B30
- * **
- * * * - F **
- H **
- L **
- N **
- R **
Reduced Size Vertical Mount
Summary of Contents for b30
Page 10: ...x B30 BUS DIFFERENTIAL SYSTEM INSTRUCTION MANUAL TABLE OF CONTENTS ...
Page 486: ...5 278 B30 BUS DIFFERENTIAL SYSTEM INSTRUCTION MANUAL TESTING CHAPTER 5 SETTINGS 5 ...
Page 616: ...iv B30 BUS DIFFERENTIAL SYSTEM INSTRUCTION MANUAL ABBREVIATIONS ...
Page 632: ...xvi B30 BUS DIFFERENTIAL SYSTEM INSTRUCTION MANUAL INDEX ...