3. Hang the blood-dispensing bag on the
stand.
4. Attach the illing tube from the right arm to
the bottom port of the blood-dispensing bag.
5. Close the adjustable clamp of the draining
tube located near the right shoulder.
6. Add water or artiicial blood to the blood-
dispensing bag using the provided funnel or
large syringe.
7. Place the drainage tube inside a container.
8. Open the adjustable clamp to allow luid
to low through the system and into the
drainage container.
9. Close the adjustable clamp of the drainage
tube.
10. Perform intravenous, subcutaneous, and
intramuscular procedures.
11. To vary the blood pressure in the vasculature
of the arm, attach the tube with squeeze bulb
to the upper port of the blood-dispensing
bag and depress the squeeze bulb.
12. Once the training session is inished, place
the drainage tube in a container and open
the adjustable clamp. Drain the luid by
raising the blood-dispensing bag above the
simulator. Alternatively, ill the syringe with
air and connect it to the upper port of the
blood-dispensing bag. Depress the syringe
to move the remaining luid from the system.
13. Flush the system with water if artiicial blood
was used to ill the veins.