| Working with Super Chloe™ | User Guide |
11
TRACHEOSTOMY CARE
The simulator is supplied with a tracheostomy
opening. Pierce the replaceable trachea and
insert a tracheostomy tube with an attached
positive pressure device to observe chest rise.
Reseal the trachea with the tape provided after
each exercise.
SURGICAL TRACHEA REPAIR
1. Lift the chest skin of the simulator to reveal
the chest cavity.
2. Locate the trachea.
3. Remove the tape enclosing the trachea.
4. Use the provided tape to replace the pierced
tape and re-seal the trachea.
5. Lay the chest skin over the torso and
reattach with Velcro.
Breathing
PULMONARY VENTILATION
Ventilate using a BVM and obtain realistic, dual
chest rise. Use a itted mask to limit air leakage
and to provide a visible chest rise.