SP16384;
Set the speed
PR10000;
Prepare mode of motion
BGX; Begin
motion
MCX
JS#CORRECT; Move
to
correction
#MOTION2
SP16384;
Set the speed
PR-10000;
Prepare mode of motion
BGX; Begin
motion
MCX
JS#CORRECT; Move
to
correction
JP#MOTION
#CORRECT; Correction
code
spx=_SPX
#LOOP;
Save speed value
SP2048;
Set a new slow correction speed
WT100; Stabilize
JP#END,@ABS[_QSX]<10; End correction if error is within defined tolerance
YRX=_QSX; Correction
move
MCX
WT100; Stabilize
JP#LOOP; Keep
correcting
until
error is within tolerance
#END;
End #CORRECT subroutine, returning to code
SPX=spx
EN
Dual Loop (Auxiliary Encoder)
The DMC-2x00 provides an interface for a second encoder for each axis except for axes configured for
stepper motor operation and any axis used in circular compare. When used, the second encoder is
typically mounted on the motor or the load, but may be mounted in any position. The most common
use for the second encoder is backlash compensation, described below.
The second encoder may be a standard quadrature type, or it may provide pulse and direction. The
controller also offers the provision for inverting the direction of the encoder rotation. The main and
the auxiliary encoders are configured with the CE command. The command form is CE a,b,c,d (or
a,b,c,d,e,f,g,h for controllers with more than 4 axes) where the parameters a,b,c,d each equal the sum
of two integers m and n. m configures the main encoder and n configures the auxiliary encoder.
NOTE:
This operation is not available for axes configured for stepper motors.
112
•
Chapter 6 Programming Motion
DMC-2X00
Summary of Contents for DMC-2010
Page 18: ...THIS PAGE LEFT BLANK INTENTIONALLY 8 Chapter 1 Overview DMC 2X00...
Page 48: ...THIS PAGE LEFT BLANK INTENTIONALLY 38 Chapter 2 Getting Started DMC 2X00...
Page 78: ...THIS PAGE LEFT BLANK INTENTIONALLY 68 Chapter 5 Command Basics DMC 2X00...
Page 180: ...THIS PAGE LEFT BLANK INTENTIONALLY 170 Chapter 7 Application Programming DMC 2X00...
Page 215: ...Dimensions for DMC 2x00 DMC 2X00 Appendices y 205...