Velocity Accuracy:
Long Term
Phase-locked, better than .005%
Short Term
System dependent
Position Range:
+/-2147483647 counts per move
Velocity Range:
Up to 12,000,000 counts/sec
servo;
3,000,000 pulses/sec-stepper
Velocity Resolution:
2 counts/sec
Motor Command Resolution:
16 bit or 0.0003 V
Variable Range:
+/-2 billion
Variable Resolution:
1
⋅
10-4
Array Size:
8000 elements, 30 arrays
Program Size:
1000 lines x 80 characters
Fast Update Rate Mode
The DMC-2x00 can operate with much faster servo update rates. This mode is known as 'fast mode'
and allows the controller to operate with the following update rates:
DMC-2x10, DMC-2x20
125 usec
DMC-2x30, DMC-2x40
250 usec
DMC-2x50, DMC-2x60
375 usec
DMC-2x70, DMC-2x80
500 usec
In order to run the DMC-2x00 motion controller in fast mode, the fast firmware must be uploaded.
This can be done through the Galil terminal software such as DMCTERM and WSDK. The fast
firmware is included with the original DMC-2x00 utilities. To set the update rate use command TM.
When the controller is operating with the fast firmware, the following functions are
disabled:
Gearing mode
Ecam mode
Pole (PL)
Analog Feedback (AF)
Stepper Motor Operation (MT 2,-2,2.5,-2.5)
Trippoints in thread 2-8
DMA channel
Tell Velocity Interrogation Command (TV)
DMC-2X00
Appendices
y
193
Summary of Contents for DMC-2010
Page 18: ...THIS PAGE LEFT BLANK INTENTIONALLY 8 Chapter 1 Overview DMC 2X00...
Page 48: ...THIS PAGE LEFT BLANK INTENTIONALLY 38 Chapter 2 Getting Started DMC 2X00...
Page 78: ...THIS PAGE LEFT BLANK INTENTIONALLY 68 Chapter 5 Command Basics DMC 2X00...
Page 180: ...THIS PAGE LEFT BLANK INTENTIONALLY 170 Chapter 7 Application Programming DMC 2X00...
Page 215: ...Dimensions for DMC 2x00 DMC 2X00 Appendices y 205...