2. HORIZONTAL MODE
2-10
3. Press the
H/V/S
key to select the [S] tab.
4. Select [Sel. TVG Curve] then push the left-click button.
5. Select a curve then push the left-click button.
The smaller the number, the gentler the gain change over distance.
6. Select [Quit] on the setting window then push the left-click button to close the box.
7. Long-press the
MENU/ESC
key to close all menus.
The TVG is also used to suppress unwanted echoes (sea surface reflections,
cruising noise, etc.) on near ranges. If the selected curve does not provide satis-
factory results, try to adjust [TVG-Near], [TVG-Medium] or [TVG-Far], as shown
below.
TVG distance and setting
This sonar has three TVG
functions, NEAR, MEDIUM
and FAR, and they mainly
compensate for propagation
loss on short, middle and long
ranges respectively, centered
at the ranges shown below.
The higher the TVG setting,
the greater the amplification
of echoes.
1. Press the
MENU/ESC
key then push the left-click button to open the main menu.
2. Select [Gain Setting] then push the left-click button.
3. Press the
H/V/S
key to select [H1] or [H2] tab.
4. Select [TVG Distance] then push the left-click button.
Approx. 100 m
Near
Far
Med
Approx. 400 m
Approx. 800 m
Summary of Contents for FSV85MK2
Page 12: ...SYSTEM CONFIGURATION xii This page is intentionally left blank ...
Page 74: ...2 HORIZONTAL MODE 2 44 This page is intentionally left blank ...
Page 128: ...4 SLANT MODE 4 36 This page is intentionally left blank ...
Page 132: ...5 NUMERIC GRAPHIC DATA DISPLAY 5 4 This page is intentionally left blank ...
Page 188: ...9 MAINTENANCE 9 24 This page is intentionally left blank ...
Page 199: ......