7. OTHERS MENU
7-5
3) Press the same function key twice within one second to
reset the timer. The timer window will change as shown
on the right.
Circle Cursor Diameter
: Sets the default diameter of the
circle cursor.
Disp. Hull Unit Status:
When set to [ON], the hull unit’s status is displayed on-screen
. Set to [OFF] to hide the status display.
7.4
Alarm & Audio Menu
The [Alarm & Audio] menu sets the fish alarm and the audio bearing mark sector. To
show this menu, open the main menu, then open the [Others] and [Alarm & Audio]
menus.
Fish Alarm
: Turns the fish alarm function on or off. The default setting is off.
Alarm Level
: Sets the minimum echo color which triggers the fish alarm. The setting
range is 0-30.
Alarm Zone
: Sets fish alarm zone.
Ship SPD Alarm
: The default setting is ON. The alarm is released if ship’s speed ex-
ceeds the following limits: Lowering transducer: 18 knots Raising transducer: 15 knots
Audio
: Turns the audio function on/off.
Audio Alarm
: Adjusts the volume of the buzzer.
Audio Sector
: Selects the audio sector width for use with audio function.
Reverberation
: Selects the length of reverberation for audio signal. The setting range
is 0-9 and 0 is no reverberation. The larger the value, the longer the reverberation.
Summary of Contents for FSV85MK2
Page 12: ...SYSTEM CONFIGURATION xii This page is intentionally left blank ...
Page 74: ...2 HORIZONTAL MODE 2 44 This page is intentionally left blank ...
Page 128: ...4 SLANT MODE 4 36 This page is intentionally left blank ...
Page 132: ...5 NUMERIC GRAPHIC DATA DISPLAY 5 4 This page is intentionally left blank ...
Page 188: ...9 MAINTENANCE 9 24 This page is intentionally left blank ...
Page 199: ......