Appendix A
Fixed Issues
91
6802433
For DC input power models, the INPUT limit
value included in the output from the
showpower -v
command may differ between
/SYS/PS0 and /SYS/PS1. The /SYS/PS1 value
is correct. For examples, see
Power Models, the Output From the
Command May Differ Between /SYS/PS0
And /SYS/PS1 (CR 6802433)” on page 109
.
Note - Fixed in System Firmware 7.2.2.e or later.
None. Ignore this issue because it is only a display
error.
6801248
For DC input power models, the following event
log might be repeatedly collected when the
power to the system is turned on:
[Sample output from the
showlogs
command]
Chassis|minor:"Error getting status
DC volt for PS0"
Chassis|minor:"Error getting status
DC volt for PS1"
Chassis|minor:"Error getting status
DC volt for PS0"
Chassis|minor:"Error getting status
DC volt for PS0"
Note - Fixed in System Firmware 7.2.2.e or later.
None. Ignore this event log.
6819987
For DC input power models, the following event
log might be repeatedly collected:
[Sample output from the
showlogs
command]
IPMI |minor : "ID = 20a : 03/11/2009
: 02:31:48 : Current :
/PS0/CUR_FAULT : State Asserted"
IPMI |minor : "ID = 20b : 03/11/2009
: 02:31:51 : Temperature :
/PS0/TEMP_FAULT : State Asserted"
IPMI |minor : "ID = 20c : 03/11/2009
: 02:31:54 : Current :
/PS0/CUR_FAULT : State Deasserted"
IPMI |minor : "ID = 20d : 03/11/2009
: 02:31:57 : Temperature :
/PS0/TEMP_FAULT : State Deasserted"
Note - Fixed in System Firmware 7.2.2.e or later.
None. If the Service Required, Overtemp, and
Power Supply Service Required LEDs on the
server are off, ignore the event log items. If one of
these LEDs is on, indicating that a power supply
problem or temperature-related problem has
occurred, correct the problem.
6821325
In the output from the
prtdiag
command,
warnings may be displayed for input voltage
sensors (V_IN_MAIN) on power supply units.
For examples, see
Displayed (CR 6821325)” on page 110
Note - Fixed in System Firmware 7.2.7.b or later.
None. Ignore this issue because it is only a display
error.
TABLE A-3
Fixed Firmware, ILOM, POST, and SP Issues
(Continued)
CR
Description
Workaround