64
SPARC Enterprise T5120 and T5220 Servers Product Notes • April 2010
SPARC Enterprise T5120 and T5220
Servers Installation Guide
This manual includes descriptions using the cable management arm (CMA);
however, the SPARC Enterprise T5120 server doesn't support the cable management
arm.
Verify Proper Seating of Preinstalled PCIe/XAUI Cards
The server installation procedure should include instructions for verifying that any
preinstalled PCIe and/or XAUI cards and their risers have not worked loose during
shipping. This procedure should also include instructions for verifying that internal
cables are properly routed and that their connections are secure.
Workaround: When installing a newly arrived server that has preinstalled PCIe
and/or XAUI cards, open it and verify that the cards and their risers are securely
seated. Also verify that the internal cables are correctly routed and securely
connected. Refer to the
SPARC Enterprise T5120 and T5220 Servers Service Manual
for
information about the PCIe/XAUI cards and their risers as well as information about
internal cable routing.
SPARC Enterprise T5120 and T5220
Servers Service Manual
Erroneous Description in the Section "Disconnect Power
Cords From the Server"
The following description in the section "Disconnect Power Cords From the Server"
is incorrect.
■
Unplug all power cords from the server.
Caution –
Because 3.3v standby power is always present in the system, you must
unplug the power cords before accessing any cold-serviceable components.