50
SPARC Enterprise T5120 and T5220 Servers Product Notes • April 2010
This event occurs in case you power off the system and remove the power cord in a
short period of time, or in case you remove and insert the power cord in a short
period of time. When the above time period is too short, the ILOM internal process
does not complete normally.
When this event occurred, perform the following procedure. After you restored
using this procedure, you do not need to replace the component.
/export/delivery/delivery/4.30/4.30.6/post4.30.6-micro/Niagara/huron/integrated
(root)
0:0:0>Copyright 2009 Sun Microsystems, Inc. All rights reserved
0:0:0>POST enabling CMP 0 threads: ffffffff.ffffffff
0:0:0>VBSC mode is: 00000000.00000001
0:0:0>VBSC level is: 00000000.00000001
0:0:0>VBSC selecting Normal mode, MAX Testing.
0:0:0>VBSC setting verbosity level 2
0:0:0>Basic Memory Tests....Done
0:0:0>Test Memory....Done
0:0:0>Setup POST Mailbox ....Done
0:0:0>Master CPU Tests Basic....Done
0:0:0>Init MMU.....
Fault | critical: SP detected fault at time Mon Jan 18 08:45:10 2010. /SYS/PADCRD
prom is unreadable or corrupted
0:0:0>NCU Setup and PIU link train....Done
0:0:0>L2 Tests....Done
0:0:0>Extended CPU Tests....Done
0:0:0>Scrub Memory....Done
0:0:0>SPU CWQ Tests...Done
0:0:0>MAU Tests...Done
0:0:0>Network Interface Unit Tests....Done
0:0:0>Functional CPU Tests....Done
0:0:0>Extended Memory Tests....Done
2010-01-18 08:46:50.299 0:0:0>INFO:
2010-01-18 08:46:50.302 0:0:0> POST Passed all devices.
2010-01-18 08:46:50.307 0:0:0>POST: Return to VBSC.
2010-01-18 08:46:50.310 0:0:0>Master set ACK for vbsc runpost command and spin...
Chassis | major: Host is running
SPARC Enterprise T5220, No Keyboard
Copyright 2009 Sun Microsystems, Inc. All rights reserved.
OpenBoot 4.30.6, 8064 MB memory available, Serial #85367270.
Ethernet address 0:21:28:16:99:e6, Host ID: 851699e6.
{0} ok