Chapter 3
Known Issues
35
6932448
With the System firmware 7.1.6.d or later, the
following type of message might be displayed
on the console and in the logs:
Chassis | major: Hot insertion of
/SYS/MB/CMP0/P0
or
SC Alert: [ID 639621 daemon.error] SC
unretrieved msg: [Chassis | major: Hot
insertion of /SYS/MB/CMP0/P3]
Chassis | major: Hot removal of HDD3
or
SC Alert: [ID 677427 daemon.error] SC
unretrieved msg: [Chassis | major: Hot
removal of HDD3]
Be aware that these messages are not necessarily
error messages.
Messages referring to hot-insertions of CPUs
and hard disks, or messages referring to hot-
insertions/removals of a nonexistent device are
displayed at power on if the system has had a
firmware upgrade or system component change.
Once the components have been identified, no
subsequent messages are displayed unless ILOM
detects a change in the system configuration or
if hardware failure occurs.
6902381
When you powered on the server, all LEDs or all
LEDs on the right side on the front panel may
light up. When using System Firmware 7.2.2.e or
later, the ILOM status check command (the
showenvironment
command) also displays the
status of relevant LED being ON; however, this
event itself is an issue absolutely limited to the
LED display and does not have an effect on the
system.
None.
When this event occurred, perform the ILOM
reset operation. If not recovered, shut down the
system and then remove and insert the power
cord.
ILOM reset operation example:
Log in to ILOM and execute the following
command.
[In case of ILOM command mode]
->
reset /SP
Are you sure you want to reset /SP
(y/n)?
y
[In case of ALOM CMT compatible shell]
sc>
resetsc
Are you sure you want to reset the
SC [y/n]?
y
11210193
If an error occurs during POST execution,
"Fault Sensor VCORE_POK at /SYS/MB
deasserted"
may be registered when the
showfaults
ALOM CMT compatibility
command is used for status confirmation.
However, POST will still end normally in this
case.
For an example, see
POST, But POST Ends Normally (CR 11210193)”
on page 48
.
None. If this problem occurs, use the
resetsc
ALOM CMT compatibility command to clear the
log and reset the LED display.
11215994
In rare circumstances, the
ok
prompt may not be
displayed normally after POST execution ends.
See
POST Ends (CR 11215994)” on page 49
TABLE 3-3
Firmware, ILOM, POST, and SP Issues
(Continued)
CR
Description
Workaround