Appendix A
Fixed Issues
87
6615884
(6614576)
The help message is incorrect in the ILOM BI.
The informational text displayed on the
Configuration Serial Port tab in the ILOM BI
refers to a DB-9 connector, but the message
should refer to the RJ-45 connector.
Note - Fixed in System Firmware 7.0.9 or later.
Be aware of this discrepancy.
6616693
When the information obtained by using IPMI,
the information such as the "Product Part
Number" of the server is not displayed correctly.
Note - Fixed in System Firmware 7.0.9 or later.
Log in to ILOM and refer to the information such
as
/SYS
.
6618773
A diagnostic routine that runs at startup (IBIST)
might disconnect the memory controller unit
(MCU), resulting in errors.
For an example of the errors, see
Routine That Runs at Startup (IBIST) Might
Accidentally Disconnect the MCU (CR 6618773)”
on page 105
Note - Fixed in System Firmware 7.1.0.g or later.
Install Patch 127580-04 or later, and update the
System Firmware to version 7.0.9 or later.
6622444
In the mirroring configuration of the system
volume disk using the PRIMECLUSTER GDS,
when an error occurred while reading the boot
block of boot disk, the boot path does not
switch. At this time, the following message
appears and the process returns to the
ok
prompt.
Boot load failed.
The file just loaded does not appear to
be executable.
{0} ok
Note - Fixed in System Firmware 7.0.9 or later.
When the process returned to the ok prompt,
reexecute the
boot
command to start the OS.
6623454
Despite the change of SSH setting from "Disable"
to "Enable" by using the "SSH Server" tab of BUI,
it is displayed as "Disable."
Note - Fixed in System Firmware 7.2.2.e or later.
The SSH setting has been changed to "Enable."
Use the Refresh function of BUI.
6624658
Unless the system is stopped from the service
processor, the system will be automatically
powered on at the next AC power-on even if the
HOST_LAST_POWER_STATE
in
/SP/policy
is
set to "
enabled
".
The same applies if the
HOST_AUTO_POWER_ON
property is set to
enabled
but the system has
not been stopped from the service processor.
Note - Fixed in System Firmware 7.1.3.d or later.
To stop the system, use the command on the
service processor.
Moreover, when setting the
HOST_AUTO_POWER_ON
property to "
enabled
",
also set the
HOST_POWER_ON_DELAY
property to
"
enabled
".
6624699
Despite the change of Role to
Administrator/Operator by using "Active
Directory" of BUI, Role is displayed as blank.
Note - Fixed in System Firmware 7.2.2.e or later.
Log in to ILOM and check the
defaultrole
property of
/SP/clients/activedirectory
.
TABLE A-3
Fixed Firmware, ILOM, POST, and SP Issues
(Continued)
CR
Description
Workaround