Chapter 3
Known Issues
23
n/a
When the system is initialized, firmware is
loaded and occupies approximately 128 MB to
352 MB of the host memory. The banner and
other software utilities report an amount of
memory minus the amount of memory that is
occupied by firmware.
When viewing the amount of memory in the
banner, be aware that the banner reports the
amount less what is used by the firmware.
n/a
An RJ45 cable may sometimes be difficult to
disconnect from an RJ45 port of an Ethernet card
mounted in the SPARC Enterprise T5120.
In this event, disconnect the cable while keeping
the RJ45 cable connector tab depressed, such as
with a plastic card.
(Bug ID
6581309)
To use the XVR-300 as a console of the SPARC
Enterprise T5xx0, patch 137111-01 or later must
be applied.
If the patch is applied after the OBP variable has
been changed to use the XVR-300 as the console,
console output will revert to the default ILOM
console during the Solaris boot sequence.
To use the XVR-300 as a console, apply patch
137111-01 or later to the Solaris OS before
changing the OBP variable.
Alternatively, install the Solaris OS (or reinstall
it) with ILOM set as the console used, and then
apply the patch.
No GUI can be used during that time.
After the patch has been applied, the XVR-300
can be used as the console as soon as the OBP
variable is changed.
6706976
At write to CD/DVD media, there may be cases
where the writing speed may not reach the
maximum speed supported by the CD/DVD
drive. Even if the maximum operation is not
reached, there are no problems in the processing
for writing to the CD/DVD media.
Use the media as is.
6840287
When a server is power cycled with DVD media
installed, the message "
Device is gone
" will
be displayed approximately 30 minutes after the
OS is booted up.
Ignore the message.
6857080
Systems with firmware version 7.2.2.x have low
fan speed (5000 rpms). The low fan speed
condition can result in SC Alerts that warn of the
low fan speed.
Ensure that the air flowing into the server is
within the ambient temperature specification.
n/a
The On/Standby portion of the service label
contains an error. It says to press and hold the
On/Standby button for “5 seconds”. It should
say “4 seconds”.
Note -
This error appears on the service labels
on all SPARC Enterprise T5120 and T5220 server
configurations.
n/a
Some service labels show an extra fan module in
step 2 of the four-step fan board diagram. The
extra fan is on the right half of FanBD0.
Note -
This error appears on the service label for
SPARC Enterprise T5120 servers with 4-disk
capable backplanes.
TABLE 3-1
Hardware and Mechanical Issues
(Continued)
CR
Description
Workaround