"Getting access to the component" on page 51
▶
"Removing the system air duct" on page 67
▶
"Removing the PCI air duct" on page 88
.
▶
Remove all expansion cards, see
.
Before removing the expansion cards, take a note on the installation
slot number for each card. Ensure that you install the card again in
the slot it was located before the replacement.
▶
If applicable,
"Removing the riser module" on page 86
.
▶
"Removing the crossbar" on page 90
▶
Remove the fan bridge, see
"Handling the fan bridge" on page 92
▶
Remove all memory modules, see
.
Before removing the memory modules, take a note on the installation
slot number for each memory module. Ensure that you install the
memory modules again in the slot they were located before the
replacement.
CAUTION
In case of NVM/LRDIMMs are not reinstalled in the right slots, data
can be lost!
▶
If applicable, remove the OCP module, see
.
▶
If applicable, remove the iRMC microSD card, see
.
▶
If applicable, remove all M.2 SSDs, see
.
Keep the screws for future use.
Removing the defective system board
▶
Disconnect all cables from the system board.
System board and components
516
Upgrade and Maintenance Manual
TX2550 M5
Summary of Contents for PRIMERGY TX2550 M5
Page 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Page 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Page 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Page 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Page 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Page 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Page 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Page 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...