Concluding steps
▶
.
▶
"Connecting the power cord" on page 82
.
▶
"Switching on the server" on page 83
.
▶
"Resuming BitLocker functionality" on page 130
7.8.2
Upgrading with non-hot-plug HDDs/SSDs
Upgrade and Repair Unit
(URU)
Hardware: 10 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
▶
"Suspending BitLocker functionality" on page 107
▶
"Shutting down the server" on page 49
▶
"Disconnecting the power cord" on page 50
▶
"Getting access to the component" on page 51
▶
"Removing the system air duct" on page 67
▶
Remove the fan bridge, see
"Handling the fan bridge" on page 92
Upgrading with non-hot-plug HDDs/SSDs
▶
Install the non-hot-plug HDDs/SSDs, see
"Installing a non-hot-plug HDD/
.
▶
Install the non-hot-plug cage, see
"Installing the non-hot-plug cage" on
.
Hard disk drive (HDD) / solid state disk (SSD)
304
Upgrade and Maintenance Manual
TX2550 M5
Summary of Contents for PRIMERGY TX2550 M5
Page 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Page 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Page 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Page 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Page 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Page 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Page 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Page 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...