HDD/SSD activity indicator (4)
Status
Description
flashing green
Data access in progress.
Power-on indicator (5)
Status
Description
off
The server is switched off.
green on
– The server has been switched on but Power Cycle
Delay settings delay it from turning on for a
specified time.
– The server is switched on and operating normally.
flashing green slowly
The BMC firmware is starting up after the server has
been connected to the mains.
AC connected indicator (6)
Status
Description
green on
– The server is switched off and connected to the
mains (standby mode).
– The server has been switched on but Power Cycle
Delay settings delay it from turning on for a
specified time.
After connecting the server to the mains, it
will take about 60 seconds until the server
will enter standby mode and can be switched
on.
off
– The server is switched off and not connected to the
mains.
– The server is switched on and operating normally.
Appendix A
572
Upgrade and Maintenance Manual
TX2550 M5
Summary of Contents for PRIMERGY TX2550 M5
Page 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Page 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Page 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Page 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Page 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Page 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Page 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Page 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...